Dedicated Outdoor Air System
- Independent Latent Control
- Measured Ventilation Air
- Energy-Recovery Ready
- Stable Dry Supply Air
Produkteinführung
A dedicated outdoor air system separates ventilation and latent treatment from the high recirculation airflow used for cleanroom particle control. It receives 100% outdoor air, recovers useful energy from a separated exhaust stream where appropriate, cools and dries the air, then reheats it to a neutral or designed supply condition. This division lets terminal recirculation units handle sensible load and filtration without relying on them to remove the full outdoor-air moisture load. Airflow, dew point and supply temperature can be monitored independently.
Key Features
Deep dehumidification establishes a predictable supply dew point across seasonal outdoor conditions.
Plate, run-around or carefully selected rotary recovery can reduce outdoor-air heating and cooling load.
Reheat prevents overcooled ventilation air from causing local discomfort or excess sensible cooling.
Kunden Produktbedenken
When ventilation air and recirculation air are treated together, moisture control can drift as outdoor conditions and room sensible loads change independently.
Typische Anwendungen
Technische Parameter
Typical double-skin construction for a cleanroom dedicated outdoor air system is listed below.
| Core Material | Closed-cell polyurethane insulation in thermally separated double-skin panels |
|---|---|
| Panel Dicke | 50–70 mm insulated casing |
| Effektive Breite | 1000–3400 mm nominal casing width |
| Maximale Länge | Up to 12000 mm including recovery, coil, reheat and fan modules |
| Stahl facing Dicke | 0.6–1.0 mm outer skin and 0.8–1.0 mm wet-section lining |
| Kerndichte | 40–45 kg/m³ closed-cell polyurethane |
| Thermische Leitfähigkeit | 0.022–0.026 W/(m·K) for the casing insulation |
| Oberfläche Finish | Powder-coated exterior with cleanable galvanized or stainless inner surfaces |
| Gemeinsamer Typ | Compression-gasketed thermal-break panels with isolated supply and exhaust air paths |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Dedicated Outdoor Air System specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.