Sistema de control AHU

A dedicated AHU automation package for fan pressure, temperature, humidity, dampers, heating and cooling coils, filters and protective operating sequences.
  • Supply-Air Condition Control
  • Fan and VFD Sequencing
  • Filter Pressure Monitoring
  • Coil and Damper Protection
Solicite un presupuesto. Browse productos

Introducción del producto

The AHU control panel combines a local controller, motor interfaces, analog inputs and protective circuits around the air-handler sequence. Supply-air temperature and humidity loops coordinate cooling, heating and humidification, while fan speed responds to duct pressure or airflow demand. Differential-pressure inputs indicate filter loading and airflow proof contacts confirm safe operation before conditioning stages are enabled. Freeze, smoke, high-temperature and fan-failure interlocks move the unit to predefined safe states.

Características clave

Coordinated heating, cooling and humidity loops reduce opposing control actions.

VFD speed control maintains supply static pressure as terminal airflow demand changes.

Filter differential pressure and fan proof signals provide early maintenance indicators.

Hardwired and programmed interlocks protect coils, heaters and downstream cleanroom zones.

Preocupaciones del producto del cliente

Cleanroom air handlers must maintain stable supply conditions while responding safely to changing airflow demand and equipment faults.

Cooling and reheat operate against each other and waste energy.Sequenced control assigns clear priority and deadbands between conditioning stages.
A loaded filter reduces room airflow before maintenance notices.Dedicated differential-pressure trends and alarm thresholds reveal increasing filter resistance.
Fan speed changes cause unstable supply-duct pressure.A tuned pressure loop modulates the VFD within defined minimum and maximum limits.
A freeze or smoke input leaves dampers and coils in an unsafe state.Interlock logic commands fans, dampers and valves to a predetermined protective sequence.

Aplicaciones típicas

Pharmaceutical makeup-air unitsCleanroom recirculation AHUsLaboratory supply systemsHumidity-controlled production areas

Parámetros técnicos

Typical physical construction for a cleanroom AHU control cabinet is listed below.

Materiales CorePowder-coated steel cabinet with FR-4 controller boards, copper distribution and flame-retardant terminal ducts
Panel de espesor300-600 mm cabinet depth
Ancho efectivo800-1600 mm cabinet width
Longitud máximaHasta 2200 mm de altura del gabinete
Acero frente a espesor1.5-2.0 mm powder-coated steel enclosure
Densidad Core7800-8050 kg/m³ for steel structural parts
Conductividad térmica45-60 W/(m·K) for steel enclosure panels
Superficie acabadaLight-gray powder coat with blue, green and red control indicators
Tipo conjuntoFloor-standing segmented cabinet with isolated motor, controller and field-terminal sections
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Dual-fan lead-lag controlHumidifier interfaceHeat-recovery sequenceLocal touchscreen HMI

Planning a AHU Control System specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.