Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Systèmes de contrôle des salles blanches et de surveillance environnementale

Z Système de contrôle AHU

A dedicated AHU automation package for fan pressure, temperature, humidity, dampers, heating and cooling coils, filters and protective operating sequences.
  • Supply-Air Condition Control
  • Fan and VFD Sequencing
  • Filter Pressure Monitoring
  • Coil and Damper Protection
Demander un devis. Browse les produits

Introduction de produit

The AHU control panel combines a local controller, motor interfaces, analog inputs and protective circuits around the air-handler sequence. Supply-air temperature and humidity loops coordinate cooling, heating and humidification, while fan speed responds to duct pressure or airflow demand. Differential-pressure inputs indicate filter loading and airflow proof contacts confirm safe operation before conditioning stages are enabled. Freeze, smoke, high-temperature and fan-failure interlocks move the unit to predefined safe states.

Key Features

Coordinated heating, cooling and humidity loops reduce opposing control actions.

VFD speed control maintains supply static pressure as terminal airflow demand changes.

Filter differential pressure and fan proof signals provide early maintenance indicators.

Hardwired and programmed interlocks protect coils, heaters and downstream cleanroom zones.

Préoccupations du client produit

Cleanroom air handlers must maintain stable supply conditions while responding safely to changing airflow demand and equipment faults.

Cooling and reheat operate against each other and waste energy.Sequenced control assigns clear priority and deadbands between conditioning stages.
A loaded filter reduces room airflow before maintenance notices.Dedicated differential-pressure trends and alarm thresholds reveal increasing filter resistance.
Fan speed changes cause unstable supply-duct pressure.A tuned pressure loop modulates the VFD within defined minimum and maximum limits.
A freeze or smoke input leaves dampers and coils in an unsafe state.Interlock logic commands fans, dampers and valves to a predetermined protective sequence.

Les applications typiques

Pharmaceutical makeup-air unitsCleanroom recirculation AHUsLaboratory supply systemsHumidity-controlled production areas

Paramètres techniques

Typical physical construction for a cleanroom AHU control cabinet is listed below.

Matériaux de basePowder-coated steel cabinet with FR-4 controller boards, copper distribution and flame-retardant terminal ducts
Panneau épaisseur300-600 mm cabinet depth
Largeur effective800-1600 mm cabinet width
Longueur maximaleJusqu'à 2200 mm de hauteur de cabinet
Acier face épaisseur1.5-2.0 mm powder-coated steel enclosure
Densité Core7800-8050 kg/m³ for steel structural parts
Conductivité thermique45-60 W/(m·K) for steel enclosure panels
surface finieLight-gray powder coat with blue, green and red control indicators
Type jointFloor-standing segmented cabinet with isolated motor, controller and field-terminal sections
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Dual-fan lead-lag controlHumidifier interfaceHeat-recovery sequenceLocal touchscreen HMI

Planning a AHU Control System specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact