클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
클린룸 제어 및 환경 모니터링 시스템 (Cleanroom Control and Environment Monitoring Systems)

AHU 제어 시스템

A dedicated AHU automation package for fan pressure, temperature, humidity, dampers, heating and cooling coils, filters and protective operating sequences.
  • Supply-Air Condition Control
  • Fan and VFD Sequencing
  • Filter Pressure Monitoring
  • Coil and Damper Protection
견적 요청 제품 찾아보기

상품 소개

The AHU control panel combines a local controller, motor interfaces, analog inputs and protective circuits around the air-handler sequence. Supply-air temperature and humidity loops coordinate cooling, heating and humidification, while fan speed responds to duct pressure or airflow demand. Differential-pressure inputs indicate filter loading and airflow proof contacts confirm safe operation before conditioning stages are enabled. Freeze, smoke, high-temperature and fan-failure interlocks move the unit to predefined safe states.

주요 기능

Coordinated heating, cooling and humidity loops reduce opposing control actions.

VFD speed control maintains supply static pressure as terminal airflow demand changes.

Filter differential pressure and fan proof signals provide early maintenance indicators.

Hardwired and programmed interlocks protect coils, heaters and downstream cleanroom zones.

고객 제품 관심사

Cleanroom air handlers must maintain stable supply conditions while responding safely to changing airflow demand and equipment faults.

Cooling and reheat operate against each other and waste energy.Sequenced control assigns clear priority and deadbands between conditioning stages.
A loaded filter reduces room airflow before maintenance notices.Dedicated differential-pressure trends and alarm thresholds reveal increasing filter resistance.
Fan speed changes cause unstable supply-duct pressure.A tuned pressure loop modulates the VFD within defined minimum and maximum limits.
A freeze or smoke input leaves dampers and coils in an unsafe state.Interlock logic commands fans, dampers and valves to a predetermined protective sequence.

일반적인 응용 프로그램

Pharmaceutical makeup-air unitsCleanroom recirculation AHUsLaboratory supply systemsHumidity-controlled production areas

기술 매개변수

Typical physical construction for a cleanroom AHU control cabinet is listed below.

핵심 재료Powder-coated steel cabinet with FR-4 controller boards, copper distribution and flame-retardant terminal ducts
패널 두께300-600 mm cabinet depth
유효 폭800-1600 mm cabinet width
최대 길이캐비닛 높이 최대 2200 mm
강철 면면 두께1.5-2.0 mm powder-coated steel enclosure
코어 밀도7800-8050 kg/m³ for steel structural parts
열전도도 (Thermal Conductivity)45-60 W/(m·K) for steel enclosure panels
표면 마무리Light-gray powder coat with blue, green and red control indicators
접합 유형Floor-standing segmented cabinet with isolated motor, controller and field-terminal sections
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Dual-fan lead-lag controlHumidifier interfaceHeat-recovery sequenceLocal touchscreen HMI

Planning a AHU Control System specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

제품

뉴스

회사 소개

문의하기