Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Sistem Kawalan Bilik Bersih dan Pemantauan Alam Sekitar

Sistem Kawalan AHU

A dedicated AHU automation package for fan pressure, temperature, humidity, dampers, heating and cooling coils, filters and protective operating sequences.
  • Supply-Air Condition Control
  • Fan and VFD Sequencing
  • Filter Pressure Monitoring
  • Coil and Damper Protection
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The AHU control panel combines a local controller, motor interfaces, analog inputs and protective circuits around the air-handler sequence. Supply-air temperature and humidity loops coordinate cooling, heating and humidification, while fan speed responds to duct pressure or airflow demand. Differential-pressure inputs indicate filter loading and airflow proof contacts confirm safe operation before conditioning stages are enabled. Freeze, smoke, high-temperature and fan-failure interlocks move the unit to predefined safe states.

Ciri-ciri Utama

Coordinated heating, cooling and humidity loops reduce opposing control actions.

VFD speed control maintains supply static pressure as terminal airflow demand changes.

Filter differential pressure and fan proof signals provide early maintenance indicators.

Hardwired and programmed interlocks protect coils, heaters and downstream cleanroom zones.

Kebimbangan Produk Pelanggan

Cleanroom air handlers must maintain stable supply conditions while responding safely to changing airflow demand and equipment faults.

Cooling and reheat operate against each other and waste energy.Sequenced control assigns clear priority and deadbands between conditioning stages.
A loaded filter reduces room airflow before maintenance notices.Dedicated differential-pressure trends and alarm thresholds reveal increasing filter resistance.
Fan speed changes cause unstable supply-duct pressure.A tuned pressure loop modulates the VFD within defined minimum and maximum limits.
A freeze or smoke input leaves dampers and coils in an unsafe state.Interlock logic commands fans, dampers and valves to a predetermined protective sequence.

Permohonan yang biasa

Pharmaceutical makeup-air unitsCleanroom recirculation AHUsLaboratory supply systemsHumidity-controlled production areas

Parameter teknikal

Typical physical construction for a cleanroom AHU control cabinet is listed below.

Bahan TerasPowder-coated steel cabinet with FR-4 controller boards, copper distribution and flame-retardant terminal ducts
Ketebalan Panel300-600 mm cabinet depth
Lebar berkesan800-1600 mm cabinet width
Panjang maksimumSehingga 2200 mm ketinggian kabinet
Keluli Menghadapi Ketebalan1.5-2.0 mm powder-coated steel enclosure
Ketumpatan teras7800-8050 kg/m³ for steel structural parts
Kekonduksian Terma45-60 W/(m·K) for steel enclosure panels
Kemasan permukaanLight-gray powder coat with blue, green and red control indicators
Jenis BersatuFloor-standing segmented cabinet with isolated motor, controller and field-terminal sections
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Dual-fan lead-lag controlHumidifier interfaceHeat-recovery sequenceLocal touchscreen HMI

Planning a AHU Control System specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami