Fotómetro de Aerosol
- Real-time aerosol penetration measurement for filter scans.
- Controlled sample flow with automatic zeroing.
- Portable interface for cleanroom validation teams.
Introducción del producto
This aerosol photometer draws a controlled sample through a light-scattering chamber and reports challenge concentration or filter penetration in real time. Dedicated upstream, downstream and clear-flow connections support the complete integrity-test sequence, while a color interface presents the baseline, alarm threshold and live scan response. The rugged portable enclosure accommodates field validation work in cleanrooms, laboratories and containment facilities.
Características clave
Automatic zero and upstream normalization reduce setup steps before scanning.
Regulated sample flow supports repeatable probe response and leak localization.
Selectable audible and visual alarms alert the operator at the chosen threshold.
Dedicated upstream, downstream and clear ports organize the sampling sequence.
Portable enclosure and probe interface support room-to-room validation work.
Preocupaciones del producto del cliente
A dependable integrity scan requires stable sample flow, a clean zero reference and immediate indication of localized aerosol penetration.
Aplicaciones típicas
Parámetros técnicos
Common construction values for portable aerosol photometers are summarized below; optical range, flow control and data features vary with the selected configuration.
| Materiales Core | Forward-scattering optical chamber, regulated sampling pump, reference filtration path and digital control electronics |
|---|---|
| Panel de espesor | Typically 1.0-2.0 mm for the protective enclosure panels |
| Ancho efectivo | Approximately 240-320 mm depending on display and valve configuration |
| Longitud máxima | Approximately 320-420 mm including sampling fittings and protective handle |
| Acero frente a espesor | Normalmente de 1,0 - 1,5 mm de acero inoxidable o revestido en polvo por |
| Densidad Core | Approximately 7900-8000 kg/m³ for stainless sample-path and enclosure components |
| Conductividad térmica | Aproximadamente 14 - 17 W / (m · K) para componentes de trayectoria de muestra inoxidable |
| Superficie acabada | Light-gray powder-coated enclosure with dark bezel, color display and stainless sampling fittings |
| Tipo conjunto | Barbed or quick-connect upstream, downstream and clear sampling ports with locking probe connector |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Aerosol Photometer specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita