Aerosol-Photometer
- Real-time aerosol penetration measurement for filter scans.
- Controlled sample flow with automatic zeroing.
- Portable interface for cleanroom validation teams.
Produkteinführung
This aerosol photometer draws a controlled sample through a light-scattering chamber and reports challenge concentration or filter penetration in real time. Dedicated upstream, downstream and clear-flow connections support the complete integrity-test sequence, while a color interface presents the baseline, alarm threshold and live scan response. The rugged portable enclosure accommodates field validation work in cleanrooms, laboratories and containment facilities.
Key Features
Automatic zero and upstream normalization reduce setup steps before scanning.
Regulated sample flow supports repeatable probe response and leak localization.
Selectable audible and visual alarms alert the operator at the chosen threshold.
Dedicated upstream, downstream and clear ports organize the sampling sequence.
Portable enclosure and probe interface support room-to-room validation work.
Kunden Produktbedenken
A dependable integrity scan requires stable sample flow, a clean zero reference and immediate indication of localized aerosol penetration.
Typische Anwendungen
Technische Parameter
Common construction values for portable aerosol photometers are summarized below; optical range, flow control and data features vary with the selected configuration.
| Core Material | Forward-scattering optical chamber, regulated sampling pump, reference filtration path and digital control electronics |
|---|---|
| Panel Dicke | Typically 1.0-2.0 mm for the protective enclosure panels |
| Effektive Breite | Approximately 240-320 mm depending on display and valve configuration |
| Maximale Länge | Approximately 320-420 mm including sampling fittings and protective handle |
| Stahl facing Dicke | Typischerweise 1,0 - 1,5 mm Edelstahl - oder pulverbeschichtete Oberfläche |
| Kerndichte | Approximately 7900-8000 kg/m³ for stainless sample-path and enclosure components |
| Thermische Leitfähigkeit | Ungefähr 14 - 17 W / (m · K) für rostfreie Probenwegkomponenten |
| Oberfläche Finish | Light-gray powder-coated enclosure with dark bezel, color display and stainless sampling fittings |
| Gemeinsamer Typ | Barbed or quick-connect upstream, downstream and clear sampling ports with locking probe connector |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Aerosol Photometer specification?