Персональный испытатель ESD
- One entry station verifies wrist-strap and independent left/right footwear grounding paths.
- Screen, high/pass/low lamps and touch electrode give operators an immediate test sequence.
- RFID-ready identification and relay options support controlled access and traceable records.
Введение продукции
This integrated entry station uses two electrically isolated stainless footwear plates, a wrist-cord socket and a broad metal touch electrode to check worn personnel grounding equipment. A blue display presents measurement or operating prompts, while separate high, pass and low lamps provide an easily recognized result. The reader area can identify authorized personnel before the test, and an optional relay or data interface can pass an approved result to a door, turnstile or local record system. The tester head is supported by a brushed-stainless post above a stable charcoal platform for repeated industrial use.
Основные характеристики
Dedicated wrist-strap socket supports worn-strap verification at the same station.
Large stainless touch electrode initiates the measurement without a mechanical key switch.
Blue display and red/green/red status lamps separate instructions from pass/fail recognition.
Integrated reader area supports RFID badge identification when specified.
Output options can interlock a door, turnstile or other EPA access device after a valid test.
Brushed-stainless contact surfaces are accessible for routine inspection and cleaning.
Обеспокоенность клиентов продуктами
An entry tester must verify several grounding paths without slowing personnel flow, associate the result with the correct operator and prevent an incomplete test from being treated as authorization.
Типичные приложения
Технические параметры
The values below describe a representative combined personnel-test station. Resistance limits, operator-identification method, result storage, communications and access-control output can be selected to match the facility ESD control plan.
| Основной материал | Brushed-stainless footwear electrodes and support post with flame-retardant ABS tester enclosure |
|---|---|
| Толщина панели | 2.0–4.0 mm molded tester-head and base-wall thickness |
| эффективная ширина | 420–560 mm usable station width |
| Максимальная длина | Up to 750 mm platform depth |
| Толщина линий стали | 1.0–1.5 mm stainless contact-plate facing thickness |
| Плотность ядра | 7800–8000 kg/m³ stainless-steel density |
| Теплопроводимость | 14–17 W/(m·K) for stainless contact and support components |
| Поверхностная отделка | Brushed stainless electrodes and post with textured charcoal housing and base |
| Объединенный тип | Isolated dual-foot plates and wrist input linked to a touch tester, display, reader and optional relay output |
| Customization | Доступно в зависимости от предполагаемого применения и операционной среды. |
Доступные варианты
Planning a ESD Personnel Tester specification?
Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

English
Немецкий
Арабский язык
Французский
Индонезийский
Японский язык
Корейский
Японский
Португальский
Русский языкТекущий
Испанский язык
Тайский
Турецкий
Вьетнамский язык