A protected microprocessor control module that interprets activation and safety inputs, regulates a compatible sliding-door motor and provides field terminals for the operator's accessory circuits.
  • Single Microprocessor PCB
  • Dual 10-Way Terminal Strips
  • Motor and Power Connectors
  • Local Two-Digit Diagnostics
Запрос котировки Просмотреть продукты

Введение продукции

This automatic door controller is the replaceable electronic command module inside an overhead pedestrian sliding-door operator. A single FR-4 circuit board carries the processor, two motor-switching relays, power-conditioning capacitor, two-position setup switch and two-digit service display beneath a light-smoke transparent cover. Two 10-way screw-terminal strips organize activation, safety, lock and accessory conductors, while separate keyed connectors distinguish the power and motor/encoder interfaces. The four-hole black mounting base fixes the module inside the operator header without presenting a user keypad or access-control reader at the doorway.

Основные характеристики

One embedded control board coordinates opening, hold-open, deceleration and closing commands from the connected operator devices.

Two separate 10-way screw-terminal strips provide orderly field termination for activation, safety, program and auxiliary circuits.

The two-digit service display and two-position setup switch support local commissioning feedback without turning the module into a public wall control.

A closed transparent service cover protects the PCB while leaving component condition and diagnostic indication visible before access is opened.

Обеспокоенность клиентов продуктами

A replacement controller must match the existing motor feedback, supply architecture, connector pinout, sensor logic and door configuration; physical resemblance alone does not establish electrical compatibility.

A controller with incompatible motor or encoder signals can drive erratically, lose position information or refuse its learning cycle.The keyed motor/encoder interface is selected against the original drive module's voltage, conductor functions and feedback format before connection.
Misplaced activation, safety or lock conductors can create unsafe sequencing even when the control board powers up normally.The two 10-way terminal groups separate field functions and are wired from the matching operator diagram rather than from terminal color alone.
Service staff may replace the board when a sensor, lock, motor or carriage fault is actually preventing door movement.The local two-digit indication is read together with input status and mechanical checks so the failed subsystem is isolated before replacement.
An exposed PCB can be damaged by dropped tools, conductive debris or accidental contact during header maintenance.The shallow transparent cover remains closed in normal service and opens only when direct terminal or component access is required.

Типичные приложения

Automatic sliding cleanroom personnel doorsAirlock and gowning-room sliding entrancesLaboratory overhead door operatorsControlled process-suite sliding doors

Технические параметры

The following conservative ranges describe compact protected controller modules used inside common single- and bi-parting pedestrian automatic sliding-door operator headers.

Основной материалFlame-retardant glass-reinforced epoxy FR-4 printed circuit board with copper conductors and polymer component housings
Толщина панели1.2-2.0 mm nominal FR-4 circuit-board thickness
эффективная ширина90-145 mm nominal controller-module width
Максимальная длинаUp to 320 mm overall mounting-base length
Толщина линий стали0.8-1.5 mm nominal plated relay-contact and connector-shell stock
Плотность ядраApproximately 1800-1900 kg/m³ for representative FR-4 laminate
ТеплопроводимостьApproximately 0.30-0.53 W/(m·K) for representative FR-4 laminate grades
Поверхностная отделкаGreen solder mask, matte-black mounting base, light-smoke transparent service cover and teal screw terminals
Объединенный типTwo 10-way PCB screw-terminal strips with separate keyed power and motor/encoder connectors on a four-hole base
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

Supply and motor interface matched to the existing operatorSingle-leaf or bi-parting door configurationCompatible lock and safety-sensor input logicConnector and mounting-base geometry matched to the service position