Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Laman Utama / Produk / Alat ganti peralatan bilik bersih / Automatic Door Controller
Alat ganti peralatan bilik bersih

Kawalan Pintu Automatik

A protected microprocessor control module that interprets activation and safety inputs, regulates a compatible sliding-door motor and provides field terminals for the operator's accessory circuits.
  • Single Microprocessor PCB
  • Dual 10-Way Terminal Strips
  • Motor and Power Connectors
  • Local Two-Digit Diagnostics
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

This automatic door controller is the replaceable electronic command module inside an overhead pedestrian sliding-door operator. A single FR-4 circuit board carries the processor, two motor-switching relays, power-conditioning capacitor, two-position setup switch and two-digit service display beneath a light-smoke transparent cover. Two 10-way screw-terminal strips organize activation, safety, lock and accessory conductors, while separate keyed connectors distinguish the power and motor/encoder interfaces. The four-hole black mounting base fixes the module inside the operator header without presenting a user keypad or access-control reader at the doorway.

Ciri-ciri Utama

One embedded control board coordinates opening, hold-open, deceleration and closing commands from the connected operator devices.

Two separate 10-way screw-terminal strips provide orderly field termination for activation, safety, program and auxiliary circuits.

The two-digit service display and two-position setup switch support local commissioning feedback without turning the module into a public wall control.

A closed transparent service cover protects the PCB while leaving component condition and diagnostic indication visible before access is opened.

Kebimbangan Produk Pelanggan

A replacement controller must match the existing motor feedback, supply architecture, connector pinout, sensor logic and door configuration; physical resemblance alone does not establish electrical compatibility.

A controller with incompatible motor or encoder signals can drive erratically, lose position information or refuse its learning cycle.The keyed motor/encoder interface is selected against the original drive module's voltage, conductor functions and feedback format before connection.
Misplaced activation, safety or lock conductors can create unsafe sequencing even when the control board powers up normally.The two 10-way terminal groups separate field functions and are wired from the matching operator diagram rather than from terminal color alone.
Service staff may replace the board when a sensor, lock, motor or carriage fault is actually preventing door movement.The local two-digit indication is read together with input status and mechanical checks so the failed subsystem is isolated before replacement.
An exposed PCB can be damaged by dropped tools, conductive debris or accidental contact during header maintenance.The shallow transparent cover remains closed in normal service and opens only when direct terminal or component access is required.

Permohonan yang biasa

Automatic sliding cleanroom personnel doorsAirlock and gowning-room sliding entrancesLaboratory overhead door operatorsControlled process-suite sliding doors

Parameter teknikal

The following conservative ranges describe compact protected controller modules used inside common single- and bi-parting pedestrian automatic sliding-door operator headers.

Bahan TerasFlame-retardant glass-reinforced epoxy FR-4 printed circuit board with copper conductors and polymer component housings
Ketebalan Panel1.2-2.0 mm nominal FR-4 circuit-board thickness
Lebar berkesan90-145 mm nominal controller-module width
Panjang maksimumUp to 320 mm overall mounting-base length
Keluli Menghadapi Ketebalan0.8-1.5 mm nominal plated relay-contact and connector-shell stock
Ketumpatan terasApproximately 1800-1900 kg/m³ for representative FR-4 laminate
Kekonduksian TermaApproximately 0.30-0.53 W/(m·K) for representative FR-4 laminate grades
Kemasan permukaanGreen solder mask, matte-black mounting base, light-smoke transparent service cover and teal screw terminals
Jenis BersatuTwo 10-way PCB screw-terminal strips with separate keyed power and motor/encoder connectors on a four-hole base
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Supply and motor interface matched to the existing operatorSingle-leaf or bi-parting door configurationCompatible lock and safety-sensor input logicConnector and mounting-base geometry matched to the service position

Planning a Automatic Door Controller specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.