Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Equipos de sala limpia piezas de repuesto

Controlador automático de puertas

A protected microprocessor control module that interprets activation and safety inputs, regulates a compatible sliding-door motor and provides field terminals for the operator's accessory circuits.
  • Single Microprocessor PCB
  • Dual 10-Way Terminal Strips
  • Motor and Power Connectors
  • Local Two-Digit Diagnostics
Solicite un presupuesto. Browse productos

Introducción del producto

This automatic door controller is the replaceable electronic command module inside an overhead pedestrian sliding-door operator. A single FR-4 circuit board carries the processor, two motor-switching relays, power-conditioning capacitor, two-position setup switch and two-digit service display beneath a light-smoke transparent cover. Two 10-way screw-terminal strips organize activation, safety, lock and accessory conductors, while separate keyed connectors distinguish the power and motor/encoder interfaces. The four-hole black mounting base fixes the module inside the operator header without presenting a user keypad or access-control reader at the doorway.

Características clave

One embedded control board coordinates opening, hold-open, deceleration and closing commands from the connected operator devices.

Two separate 10-way screw-terminal strips provide orderly field termination for activation, safety, program and auxiliary circuits.

The two-digit service display and two-position setup switch support local commissioning feedback without turning the module into a public wall control.

A closed transparent service cover protects the PCB while leaving component condition and diagnostic indication visible before access is opened.

Preocupaciones del producto del cliente

A replacement controller must match the existing motor feedback, supply architecture, connector pinout, sensor logic and door configuration; physical resemblance alone does not establish electrical compatibility.

A controller with incompatible motor or encoder signals can drive erratically, lose position information or refuse its learning cycle.The keyed motor/encoder interface is selected against the original drive module's voltage, conductor functions and feedback format before connection.
Misplaced activation, safety or lock conductors can create unsafe sequencing even when the control board powers up normally.The two 10-way terminal groups separate field functions and are wired from the matching operator diagram rather than from terminal color alone.
Service staff may replace the board when a sensor, lock, motor or carriage fault is actually preventing door movement.The local two-digit indication is read together with input status and mechanical checks so the failed subsystem is isolated before replacement.
An exposed PCB can be damaged by dropped tools, conductive debris or accidental contact during header maintenance.The shallow transparent cover remains closed in normal service and opens only when direct terminal or component access is required.

Aplicaciones típicas

Automatic sliding cleanroom personnel doorsAirlock and gowning-room sliding entrancesLaboratory overhead door operatorsControlled process-suite sliding doors

Parámetros técnicos

The following conservative ranges describe compact protected controller modules used inside common single- and bi-parting pedestrian automatic sliding-door operator headers.

Materiales CoreFlame-retardant glass-reinforced epoxy FR-4 printed circuit board with copper conductors and polymer component housings
Panel de espesor1.2-2.0 mm nominal FR-4 circuit-board thickness
Ancho efectivo90-145 mm nominal controller-module width
Longitud máximaUp to 320 mm overall mounting-base length
Acero frente a espesor0.8-1.5 mm nominal plated relay-contact and connector-shell stock
Densidad CoreApproximately 1800-1900 kg/m³ for representative FR-4 laminate
Conductividad térmicaApproximately 0.30-0.53 W/(m·K) for representative FR-4 laminate grades
Superficie acabadaGreen solder mask, matte-black mounting base, light-smoke transparent service cover and teal screw terminals
Tipo conjuntoTwo 10-way PCB screw-terminal strips with separate keyed power and motor/encoder connectors on a four-hole base
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Supply and motor interface matched to the existing operatorSingle-leaf or bi-parting door configurationCompatible lock and safety-sensor input logicConnector and mounting-base geometry matched to the service position