Тепловой насос воздуха-воды

A reversible outdoor unit that produces chilled or hot water for cleanroom air-handling coils using one refrigerant circuit and ambient air heat exchange.
  • Reversible Heating and Cooling
  • Air-Source Heat Exchange
  • Integrated Hydronic Options
  • Seasonal Capacity Modulation
Запрос котировки Просмотреть продукты

Введение продукции

The air-to-water heat pump reverses refrigerant flow so its water heat exchanger can either remove heat from the chilled-water loop or add heat to a hot-water loop. Outdoor finned coils exchange energy with ambient air, while scroll compressors and electronic expansion control adapt to seasonal conditions. The unit can serve four-pipe changeover coils, cleanroom support AHUs or low-temperature hot-water systems. Heating operation includes frost detection and defrost sequencing to restore outdoor-coil airflow.

Основные характеристики

One outdoor package supplies chilled water in cooling mode and low-temperature hot water in heating mode.

Reversible refrigerant circuitry reduces separate boiler and chiller equipment for suitable load profiles.

Variable or staged scroll compressors follow seasonal building demand and improve part-load control.

Integrated defrost management protects heating capacity as frost accumulates on the outdoor coil.

Обеспокоенность клиентов продуктами

Air-source heating performance changes with outdoor temperature and frost, so water temperature, coil selection and backup strategy must be considered together.

Heating capacity falls during the coldest outdoor conditions.Equipment sizing considers low-ambient capacity and a staged supplemental heat source where required.
Defrost temporarily reduces delivered hot-water capacity.Buffer volume and coordinated multi-module sequencing limit water-temperature disturbance.
A high hot-water setpoint forces excessive compressor lift.AHU coils are selected for the lowest practical water temperature to improve heat-pump operation.
Flow stops while the outdoor unit remains exposed to freezing weather.Flow proof, freeze protection and an appropriate glycol concentration protect the water circuit.

Типичные приложения

Cleanroom AHU heating and coolingLaboratory four-pipe changeover systemsMedical-device facilitiesPharmaceutical support buildingsLow-temperature hydronic heating

Технические параметры

Typical outdoor enclosure and hydronic insulation data for a commercial air-to-water heat pump are shown below.

Основной материалClosed-cell EPDM elastomeric foam on outdoor hydronic piping and the plate heat exchanger
Толщина панели1.0–1.5 mm removable outdoor enclosure panels
эффективная ширина900–2400 mm nominal equipment width
Максимальная длинаUp to 7500 mm for multi-circuit air-source arrangement
Толщина линий стали1.0–2.0 mm galvanized base and weather enclosure
Плотность ядра60–75 kg/m³ closed-cell EPDM tube insulation
Теплопроводимость≤0.041 W/(m·K) at 0°C for the EPDM insulation
Поверхностная отделкаOutdoor powder-coated galvanized steel with coated aluminum finned coils available
Объединенный типWelded structural base with bolted service panels and grooved hydronic connections
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

Cooling-only or reversible heat-pump operationFixed-stage or inverter scroll compressorsIntegrated pump, expansion vessel and buffer tankLow-ambient, low-noise and corrosion-protected coil packages