Luft-zu - Wasser-Wärmepumpe
- Reversible Heating and Cooling
- Air-Source Heat Exchange
- Integrated Hydronic Options
- Seasonal Capacity Modulation
Produkteinführung
The air-to-water heat pump reverses refrigerant flow so its water heat exchanger can either remove heat from the chilled-water loop or add heat to a hot-water loop. Outdoor finned coils exchange energy with ambient air, while scroll compressors and electronic expansion control adapt to seasonal conditions. The unit can serve four-pipe changeover coils, cleanroom support AHUs or low-temperature hot-water systems. Heating operation includes frost detection and defrost sequencing to restore outdoor-coil airflow.
Key Features
Reversible refrigerant circuitry reduces separate boiler and chiller equipment for suitable load profiles.
Variable or staged scroll compressors follow seasonal building demand and improve part-load control.
Integrated defrost management protects heating capacity as frost accumulates on the outdoor coil.
Kunden Produktbedenken
Air-source heating performance changes with outdoor temperature and frost, so water temperature, coil selection and backup strategy must be considered together.
Typische Anwendungen
Technische Parameter
Typical outdoor enclosure and hydronic insulation data for a commercial air-to-water heat pump are shown below.
| Core Material | Closed-cell EPDM elastomeric foam on outdoor hydronic piping and the plate heat exchanger |
|---|---|
| Panel Dicke | 1.0–1.5 mm removable outdoor enclosure panels |
| Effektive Breite | 900–2400 mm nominal equipment width |
| Maximale Länge | Up to 7500 mm for multi-circuit air-source arrangement |
| Stahl facing Dicke | 1.0–2.0 mm galvanized base and weather enclosure |
| Kerndichte | 60–75 kg/m³ closed-cell EPDM tube insulation |
| Thermische Leitfähigkeit | ≤0.041 W/(m·K) at 0°C for the EPDM insulation |
| Oberfläche Finish | Outdoor powder-coated galvanized steel with coated aluminum finned coils available |
| Gemeinsamer Typ | Welded structural base with bolted service panels and grooved hydronic connections |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Air-to-Water Heat Pump Unit specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.