Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Controle de sala limpa e sistemas de monitoramento ambiental

Sensor de VOC

A metal-oxide air quality sensor that tracks changing mixtures of volatile organic compounds and provides a compensated trend signal for ventilation or monitoring.
  • Metal-Oxide VOC Detection
  • Mixed-Gas Trend Signal
  • Humidity Compensation
  • Ventilation Control Output
Solicite um orçamento. Browse produtos

Introdução do produto

The VOC air quality sensor uses a heated metal-oxide element whose surface resistance changes when reducing or oxidizing organic vapors are present. Embedded algorithms compensate for temperature and humidity effects and convert the raw response into a VOC index or equivalent concentration trend. The device is intended for changes in mixed indoor VOC load rather than identification of one specific compound. A ventilated wall or duct enclosure exposes the element to the monitored air while keeping power and communication terminals protected.

Características-chave

Metal-oxide sensing responds to a broad range of common organic vapor changes.

Temperature and humidity compensation stabilizes the index across normal room conditions.

A trend-oriented output supports demand ventilation and environmental anomaly detection.

Wall and duct formats place the sensor where solvent or cleaning-vapor changes occur.

Preocupações do produto do cliente

A broad VOC sensor reacts to mixtures and background changes, so it should not be treated as a compound-specific analytical instrument.

Users expect one VOC index to identify an individual chemical.The system presents the reading as a mixed-gas trend and uses compound-specific detectors where selectivity is required.
Humidity changes create an apparent VOC shift during HVAC transitions.Integrated humidity compensation reduces normal environmental cross-sensitivity.
A freshly installed sensor needs time to establish a stable background.Warm-up and baseline handling allow the metal-oxide element to settle before alarm evaluation.
Cleaning spray contacts the sensing surface directly.Protected diffusion openings and appropriate mounting separate the element from liquid droplets.

Aplicações típicas

Cleanroom solvent-vapor trendingCleaning process monitoringLaboratory air qualityVentilation demand indication

Parâmetros técnicos

Typical construction values for a cleanroom VOC air quality sensor are shown below.

Material principalMetal-oxide semiconductor sensing element on FR-4 board in flame-retardant polycarbonate enclosure
Painel de espessura25-45 mm housing depth
Largura efetiva80-120 mm housing width
Comprimento máximoUp to 150 mm enclosure height
Aço enfrentando espessura0 mm; non-metallic sensor housing
Densidade Core1180-1220 kg/m³ for polycarbonate enclosure parts
Condutividade térmica0.19-0.22 W/(m·K) for polycarbonate housing material
Superfície acabadoMatte white housing with blue air-quality indicator and protected vent pattern
Tipo conjuntoSnap-fit wall enclosure with rear terminal block and replaceable vent filter
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

VOC index or equivalent concentration outputWall or duct mountAnalog or digital communicationIntegrated temperature and humidity compensation

Planning a VOC Sensor specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe