Controle de sala limpa e sistemas de monitoramento ambiental

Transmissor de pressão diferencial

A wall-mounted transmitter that converts low differential pressure into a stable analog or digital signal for cleanroom controllers and monitoring systems.
  • Field-Selectable Pressure Ranges
  • Analog and Network Outputs
  • Stable Zero Reference
  • Service-Friendly Enclosure
Solicite um orçamento. Browse produtos

Introdução do produto

The differential pressure transmitter combines a compensated sensing element, signal conditioning and field terminals in a protective enclosure. Selectable ranges let one hardware platform serve room pressure, filter loading and low-pressure duct applications while preserving appropriate resolution. Voltage or current output integrates with standard controllers, and selected versions add a digital network interface or local display. Removable terminals and front-access zero control simplify service without disturbing the wall-mounted tubing arrangement.

Características-chave

Multiple selectable ranges adapt the transmitter to rooms, filters or duct pressure.

Stable voltage or current output provides a standard signal for PLC, DDC and EMS inputs.

Front-access zero adjustment supports maintenance without removing pressure tubing.

A protected enclosure separates field wiring from the pneumatic sensing section.

Preocupações do produto do cliente

A transmitter must preserve low-pressure resolution while offering field wiring, range selection and service access suitable for installed systems.

One fixed range cannot cover rooms, filters and ducts without poor resolution.Selectable full-scale ranges match the signal span to each measurement point.
A controller input requires current output but the transmitter provides voltage only.Configurable voltage and current signals support common building-control input types.
Zero checks require disconnecting tubing and rewiring the device.Front-access controls and removable terminals simplify in-place maintenance.
Condensation or dust reaches the circuit compartment through field entries.Separated pneumatic and wiring zones with sealed cable entries protect the electronics.

Aplicações típicas

Cleanroom differential monitoringHEPA filter differential monitoringDuct static pressureAirflow pickup conversion

Parâmetros técnicos

Typical construction values for a wall-mounted low differential pressure transmitter are shown below.

Material principalSilicon MEMS element in flame-retardant polymer enclosure with nickel-plated brass tubing ports
Painel de espessura45-75 mm transmitter depth
Largura efetiva90-140 mm housing width
Comprimento máximoUp to 180 mm housing height
Aço enfrentando espessura0 mm; impact-resistant polymer enclosure
Densidade Core1180-1450 kg/m³ for polymer enclosure components
Condutividade térmica0.19-0.35 W/(m·K) for polymer housing material
Superfície acabadoSmooth light-gray housing with blue range label and transparent service cover
Tipo conjuntoDual barbed pressure ports with removable screw terminals and sealed cable entry
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Voltage or 4-20 mA outputBidirectional pressure rangesLocal LCDBACnet or Modbus output

Planning a Differential Pressure Transmitter specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe