Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Control de salas limpias y sistemas de monitoreo ambiental

Transmisor de presión diferencial

A wall-mounted transmitter that converts low differential pressure into a stable analog or digital signal for cleanroom controllers and monitoring systems.
  • Field-Selectable Pressure Ranges
  • Analog and Network Outputs
  • Stable Zero Reference
  • Service-Friendly Enclosure
Solicite un presupuesto. Browse productos

Introducción del producto

The differential pressure transmitter combines a compensated sensing element, signal conditioning and field terminals in a protective enclosure. Selectable ranges let one hardware platform serve room pressure, filter loading and low-pressure duct applications while preserving appropriate resolution. Voltage or current output integrates with standard controllers, and selected versions add a digital network interface or local display. Removable terminals and front-access zero control simplify service without disturbing the wall-mounted tubing arrangement.

Características clave

Multiple selectable ranges adapt the transmitter to rooms, filters or duct pressure.

Stable voltage or current output provides a standard signal for PLC, DDC and EMS inputs.

Front-access zero adjustment supports maintenance without removing pressure tubing.

A protected enclosure separates field wiring from the pneumatic sensing section.

Preocupaciones del producto del cliente

A transmitter must preserve low-pressure resolution while offering field wiring, range selection and service access suitable for installed systems.

One fixed range cannot cover rooms, filters and ducts without poor resolution.Selectable full-scale ranges match the signal span to each measurement point.
A controller input requires current output but the transmitter provides voltage only.Configurable voltage and current signals support common building-control input types.
Zero checks require disconnecting tubing and rewiring the device.Front-access controls and removable terminals simplify in-place maintenance.
Condensation or dust reaches the circuit compartment through field entries.Separated pneumatic and wiring zones with sealed cable entries protect the electronics.

Aplicaciones típicas

Cleanroom differential monitoringHEPA filter differential monitoringDuct static pressureAirflow pickup conversion

Parámetros técnicos

Typical construction values for a wall-mounted low differential pressure transmitter are shown below.

Materiales CoreSilicon MEMS element in flame-retardant polymer enclosure with nickel-plated brass tubing ports
Panel de espesor45-75 mm transmitter depth
Ancho efectivo90-140 mm housing width
Longitud máximaUp to 180 mm housing height
Acero frente a espesor0 mm; impact-resistant polymer enclosure
Densidad Core1180-1450 kg/m³ for polymer enclosure components
Conductividad térmica0.19-0.35 W/(m·K) for polymer housing material
Superficie acabadaSmooth light-gray housing with blue range label and transparent service cover
Tipo conjuntoDual barbed pressure ports with removable screw terminals and sealed cable entry
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Voltage or 4-20 mA outputBidirectional pressure rangesLocal LCDBACnet or Modbus output

Planning a Differential Pressure Transmitter specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto