Penukar haba plat dan bingkai gasketed
- Compact Counter-Current Transfer
- Expandable Plate Pack
- Accessible Gasketed Channels
- Hydraulic Circuit Separation
Pengenalan Produk
Corrugated stainless plates are compressed between a fixed frame and a movable pressure plate to create alternating hot and cold channels. Elastomer gaskets direct each fluid through its assigned channels without mixing. Turbulent counter-current flow supports close temperature approach in a much smaller footprint than many shell-and-tube arrangements, while loosening the tie bolts opens the pack for inspection or capacity changes.
Ciri-ciri Utama
Alternating gasketed channels keep building water separate from clean process, glycol or heat-recovery circuits.
The plate pack can be opened for mechanical cleaning and individual plate or gasket replacement.
Additional compatible plates increase surface area without replacing the main frame.
Kebimbangan Produk Pelanggan
A hydronic interface must transfer the design load with low approach temperature while keeping unlike water circuits isolated.
Permohonan yang biasa
Parameter teknikal
Representative construction data for a commercial HVAC gasketed plate exchanger are provided below.
| Bahan Teras | Corrugated AISI 304 or 316 stainless steel plate pack with elastomer gaskets |
|---|---|
| Ketebalan Panel | 0.4-0.7 mm heat-transfer plate thickness |
| Lebar berkesan | 250-1200 mm plate and frame width |
| Panjang maksimum | Up to 2400 mm frame depth along the plate-pack compression axis |
| Keluli Menghadapi Ketebalan | 12-40 mm carbon-steel fixed and pressure plates |
| Ketumpatan teras | Approximately 7900-8000 kg/m³ for stainless heat-transfer plates |
| Kekonduksian Terma | Approximately 14-16 W/(m·K) for austenitic stainless plate material |
| Kemasan permukaan | Pressed stainless plate surface with epoxy-painted carbon-steel frame |
| Jenis Bersatu | Gasketed alternating plate channels compressed by bolted tie rods with flanged ports |
| Penyesuaian | Boleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi. |
Pilihan yang boleh didapati
Planning a Gasketed Plate-and-Frame Heat Exchanger specification?
Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Bahasa Inggeris
Bahasa Jerman
Bahasa Arab (Bahasa Melayu)
Bahasa Perancis
Bahasa Indonesia: Bahasa Indonesia
Bahasa Jepun
Bahasa Korea (Bahasa Melayu)
Bahasa Melayu (Bahasa Melayu)Semasa
Bahasa Portugis: Bahasa Portugis: Bahasa Portugis
Bahasa Rusia
Bahasa Sepanyol: Bahasa Sepanyol: Bahasa Sepanyol
Bahasa Melayu (Bahasa Melayu)
Bahasa Turki: Bahasa Turki
Bahasa Vietnam (Bahasa Melayu)