クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
クリーンルーム試験 · 検証機器

温度マッピングシステム

A portable multi-channel data acquisition system for synchronized wired temperature mapping in sterilizers, chambers, freezers and other controlled thermal equipment.
  • Synchronized multi-point mapping.
  • Modular wired sensor inputs.
  • Stand-alone touch operation.
見積もりリクエスト 製品案内

商品紹介

This compact mapping platform combines a rugged measurement mainframe, a local touch interface and removable thermocouple input modules in one transportable enclosure. Multiple sensors are sampled against a common clock so engineers can compare temperature distribution across a chamber or load throughout the same study. Internal storage preserves the run locally, while network and USB interfaces support study transfer and analysis without tying the instrument to a general-purpose computer during collection.

主要な特徴

Synchronized multi-channel acquisition reveals spatial hot and cold zones.

Removable input modules simplify sensor replacement and configuration changes.

Local touch controls support stand-alone study setup and live review.

Cold-junction compensation stabilizes thermocouple measurements at the input bank.

Internal memory safeguards complete mapping records if the network is unavailable.

Battery-backed operation helps a study continue through brief supply interruptions.

お客様の製品に関する懸念事項

Thermal equipment can meet a controller setpoint while still containing local hot or cold zones, so qualification requires simultaneous measurements distributed throughout the usable volume or process load.

Independent spot readings cannot show how the whole chamber behaves at the same moment.Common-clock channel scanning produces time-aligned measurements from every mapped location.
A sensor fault can invalidate a long qualification run.Live channel status and removable input modules help identify an open or unstable sensor before the study proceeds.
Network loss may interrupt data collection in remote equipment areas.Stand-alone controls and internal memory keep the acquisition task local to the instrument.
Different assets require different channel counts and sensor types.Modular inputs and selectable thermocouple configurations adapt the platform to each mapping plan.

典型的な用途

Steam sterilizer temperature mappingDry-heat oven and depyrogenation studiesStability chamber qualificationRefrigerator and freezer distribution studiesLyophilizer shelf and chamber mapping

技術的なパラメータ

Representative portable mapping-system construction is listed below; channel count, thermocouple type and communication accessories can be selected for the intended study.

コア材料Powder-coated aluminum chassis, polycarbonate control bezel, measurement electronics and removable thermocouple input modules
パネルの厚さTypically 1.5-2.0 mm for aluminum enclosure panels
有効幅Approximately 300-420 mm across the portable mainframe
最大長さApproximately 350-480 mm including the folded transport-handle profile
鋼鉄の厚さを直面するTypically 0.8-1.2 mm for internal shielding and module-retaining plates
コア密度Approximately 2700 kg/m³ for the aluminum chassis
熱伝導率Approximately 167-205 W/(m·K) for the aluminum chassis
表面仕上げOff-white powder-coated enclosure with dark-navy molded bezel and orange sensor-port identifiers
ジョイントタイプKeyed removable multi-channel input modules with thermocouple terminals plus USB and Ethernet data interfaces
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Type T thermocouple modulesType J or K thermocouple modulesFour-channel and twelve-channel input arraysBattery backupUSB and Ethernet communication保護輸送ケース

Planning a Temperature Mapping System specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat

ホーム

製品

ニュース

会社概要

お問い合わせ