WFI Distribusi Loop
- Insulated continuous hot circulation
- Drainable low-hold-up user branches
- Integrated thermal control and sanitization interface
Perkenalan produk
This WFI distribution module combines a hygienic circulation pump, insulated supply and return headers, thermal-control exchanger and short point-of-use branches on one open skid. Continuous return flow and measured temperature support the selected hot-storage or periodic thermal-sanitization strategy while keeping serviceable components accessible.
Fitur utama:
Insulated supply and return headers
Hygienic centrifugal circulation pump
Drainable point-of-use branch geometry
Loop heat exchanger with isolated utility circuit
Temperature, pressure and conductivity monitoring
Automated steam or hot-water control interface
Local cabinet for pump and sanitization sequences
Kekhawatiran produk pelanggan
A WFI network must sustain circulation and controlled temperature without creating cool pockets, long branches or difficult-to-drain utility interfaces.
Aplikasi yang Tipis
Parameter teknis
The loop skid is configured around storage temperature, return-temperature target, distribution length, peak demand and sanitization method.
| Bahan inti | 316L stainless steel product-contact tubing, fittings, valve bodies, pump and exchanger surfaces |
|---|---|
| Ketebalan Panel (Panel Thickness) | Control cabinet and skid sheet components typically 1.5–3.0 mm |
| Efektif lebar | Packaged hot-loop skid width typically 1200–2600 mm |
| Panjang maksimum | Packaged distribution module length typically up to 4500 mm |
| Baja menghadap ketebalan | Stainless insulation cladding and cabinet facing typically 0.8–2.0 mm |
| Kepadatan inti (core density) | 316L stainless steel kepadatan sekitar 8000 kg / m3 |
| Konduktivitas Termal (Thermal Conductivity) | Typical hygienic insulation system approximately 0.035–0.045 W/(m·K) |
| Permukaan selesai | Polished or electropolished wetted surfaces with cleanable satin stainless insulation cladding |
| Jenis Bersama | Orbital-welded main tubing with drainable sanitary service connections |
| Customization (Kustomisasi) | Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi. |
Pilihan yang tersedia
Planning a WFI Distribution Loop specification?
Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.