Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
Open mobile navigationClose mobile navigation
Beranda / Produk / Sistem Distribusi Udara Cleanroom / Combination Fire and Smoke Damper
Sistem Distribusi Udara Cleanroom

Kombinasi Fire dan Smoke Damper

An actuated multiblade assembly that restricts smoke leakage during control sequences and closes the protected duct opening when its thermal release operates.
  • Dual Fire and Smoke Function
  • Sealed Airfoil Blade Bank
  • Spring-Return Safety Actuator
  • Open-Close Position Feedback
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The combination fire and smoke damper integrates a sealed multiblade smoke-control assembly with a thermally responsive closure device in one sleeved penetration unit. During normal operation the external actuator can open, close or modulate the airfoil blades for system sequences. A smoke-control command drives the spring-return actuator toward its safety position, while the thermal release provides an independent response to elevated temperature. Blade and jamb seals restrict leakage, and end switches can report the fully open and fully closed positions.

Fitur utama:

One sleeved assembly performs both duct-penetration fire closure and powered smoke isolation functions.

Airfoil blades reduce operating pressure drop while edge and jamb seals improve closed-position smoke control.

A spring-return actuator drives the selected safety position when control power is removed.

Thermal release and optional position switches support independent closure response and remote status monitoring.

Kekhawatiran produk pelanggan

Combined protection depends on correct installation at the rated opening, adequate actuator torque, intact blade seals and a control sequence that distinguishes smoke response from normal HVAC operation.

Separate fire and smoke dampers require extra duct length and two access locations.A single combination assembly consolidates thermal closure, sealed blades and actuation at one penetration.
A weak actuator cannot close the blade bank against fan pressure and seal friction.The spring-return torque is selected from damper area, blade arrangement and maximum differential pressure.
Operators cannot tell whether the damper reached its commanded safety position.Blade-linked open and closed switches provide status independent of the controller command signal.
Seal damage goes unnoticed because only actuator movement is tested.Periodic access to the blade edges and jambs allows the mechanical closure and compressible seals to be inspected together.

Aplikasi yang Tipis

Cleanroom fire and smoke compartment boundariesHospital smoke-control zonesLaboratory supply and exhaust penetrationsPharmaceutical production corridorsHigh-rise HVAC shafts and floors

Parameter teknis

Typical mechanical construction ranges for a rectangular combination fire and smoke damper are listed below.

Bahan intiGalvanized-steel airfoil blades with silicone or TPE smoke seals, steel shafts and thermal release
Ketebalan Panel (Panel Thickness)1.2–1.5 mm fabricated airfoil blade skins and frame components
Efektif lebar152–1219 mm nominal single-section opening width
Panjang maksimumUp to 1880 mm nominal single-section opening height
Baja menghadap ketebalan1.2–1.5 mm galvanized sleeve and damper frame
Kepadatan inti (core density)Approximately 7850 kg/m³ for galvanized steel blades and frame
Konduktivitas Termal (Thermal Conductivity)Approximately 45–55 W/(m·K) for carbon-steel airflow components
Permukaan selesaiMill-galvanized blade, frame and sleeve with heat-resistant seals and protected actuator bracket
Jenis BersamaSleeved flanged frame with linked sealed blades, spring-return actuator and thermal closure device
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

1.5-hour or 3-hour construction family24 V, 120 V or 230 V spring-return actuatorAuxiliary open-close indicationGalvanized, 304 or 316 stainless-steel airflow components