클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
/ 제품 / 클린룸 공기 분배 시스템 / Combination Fire and Smoke Damper
클린룸 공기 분배 시스템

Combined Fire and Smoke Damper (화염 및 연기 댐퍼)

An actuated multiblade assembly that restricts smoke leakage during control sequences and closes the protected duct opening when its thermal release operates.
  • Dual Fire and Smoke Function
  • Sealed Airfoil Blade Bank
  • Spring-Return Safety Actuator
  • Open-Close Position Feedback
견적 요청 제품 찾아보기

상품 소개

The combination fire and smoke damper integrates a sealed multiblade smoke-control assembly with a thermally responsive closure device in one sleeved penetration unit. During normal operation the external actuator can open, close or modulate the airfoil blades for system sequences. A smoke-control command drives the spring-return actuator toward its safety position, while the thermal release provides an independent response to elevated temperature. Blade and jamb seals restrict leakage, and end switches can report the fully open and fully closed positions.

주요 기능

One sleeved assembly performs both duct-penetration fire closure and powered smoke isolation functions.

Airfoil blades reduce operating pressure drop while edge and jamb seals improve closed-position smoke control.

A spring-return actuator drives the selected safety position when control power is removed.

Thermal release and optional position switches support independent closure response and remote status monitoring.

고객 제품 관심사

Combined protection depends on correct installation at the rated opening, adequate actuator torque, intact blade seals and a control sequence that distinguishes smoke response from normal HVAC operation.

Separate fire and smoke dampers require extra duct length and two access locations.A single combination assembly consolidates thermal closure, sealed blades and actuation at one penetration.
A weak actuator cannot close the blade bank against fan pressure and seal friction.The spring-return torque is selected from damper area, blade arrangement and maximum differential pressure.
Operators cannot tell whether the damper reached its commanded safety position.Blade-linked open and closed switches provide status independent of the controller command signal.
Seal damage goes unnoticed because only actuator movement is tested.Periodic access to the blade edges and jambs allows the mechanical closure and compressible seals to be inspected together.

일반적인 응용 프로그램

Cleanroom fire and smoke compartment boundariesHospital smoke-control zonesLaboratory supply and exhaust penetrations제약 생산 코리더High-rise HVAC shafts and floors

기술 매개변수

Typical mechanical construction ranges for a rectangular combination fire and smoke damper are listed below.

핵심 재료Galvanized-steel airfoil blades with silicone or TPE smoke seals, steel shafts and thermal release
패널 두께1.2–1.5 mm fabricated airfoil blade skins and frame components
유효 폭152–1219 mm nominal single-section opening width
최대 길이Up to 1880 mm nominal single-section opening height
강철 면면 두께1.2–1.5 mm galvanized sleeve and damper frame
코어 밀도Approximately 7850 kg/m³ for galvanized steel blades and frame
열전도도 (Thermal Conductivity)Approximately 45–55 W/(m·K) for carbon-steel airflow components
표면 마무리Mill-galvanized blade, frame and sleeve with heat-resistant seals and protected actuator bracket
접합 유형Sleeved flanged frame with linked sealed blades, spring-return actuator and thermal closure device
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

1.5-hour or 3-hour construction family24 V, 120 V or 230 V spring-return actuatorAuxiliary open-close indicationGalvanized, 304 or 316 stainless-steel airflow components

Planning a Combination Fire and Smoke Damper specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

제품

뉴스

회사 소개

문의하기