موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
أنظمة توزيع الهواء في الغرف النظيفة

Variable الهواء حجم التحكم المثبط صمام التحكم في تدفق الهواء

A sensor-equipped modulating damper that compares measured airflow with a remote setpoint and repositions opposed blades as demand changes.
  • Closed-Loop Airflow Control
  • Averaging Pressure Sensor
  • Modulating Opposed Blades
  • BMS Setpoint Interface
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The variable air volume control damper combines a rectangular galvanized casing, opposed control blades, an averaging differential-pressure sensor and a matched electronic controller-actuator assembly. Pressure measured at several points across the inlet is converted into an airflow signal and compared with the commanded setpoint. The actuator then moves the blade bank until the measured value returns to the required range. Replaceable edge seals and enclosed blade gears support low-leakage shut-off and keep the linkage outside the main airstream.

الخصائص الرئيسية

Multi-point effective-pressure sensing averages the inlet profile instead of relying on a single pressure tap.

Opposed airfoil blades provide progressive modulation across a broad minimum-to-maximum airflow range.

The controller can accept an analog or digital setpoint for temperature, occupancy or room-pressure sequences.

External electronics, shaft indication and replaceable seals simplify functional checks without removing the damper.

مخاوف المنتج للعملاء

Accurate VAV control depends on a usable sensor signal, stable inlet conditions, correct actuator authority and a minimum airflow that protects the room process.

A single pressure pickup reports an incorrect flow value behind an elbow.An averaging sensor samples several locations and a straight inlet section reduces profile distortion.
The actuator hunts because the controller gain is too aggressive for the duct response.Matched actuator timing and tuned control parameters provide stable movement around the airflow setpoint.
Closing below the validated minimum airflow disrupts room pressure and dilution.Programmable minimum and maximum limits keep the commanded airflow inside the operating envelope.
Blade leakage prevents an unused branch from isolating during setback.Tip and jamb seals combined with opposed blades improve shut-off when the controller receives a close override.

تطبيقات نموذجية

Cleanroom supply-air modulationLaboratory room exhaust controlPressure-cascade airflow trackingDemand-controlled pharmaceutical support roomsVariable-volume healthcare ventilation

المعلمات الفنية

Typical mechanical construction ranges for a rectangular electronic VAV control damper are listed below.

المواد الأساسيةGalvanized-steel opposed control blades with TPE seals and aluminum averaging pressure sensor
سمك اللوحة0.8–1.5 mm blade and casing components
العرض الفعال200–1000 mm nominal rectangular airway width
الحد الأقصى الطولUp to 1200 mm casing length with acoustic cladding or service section
الصلب يواجه سمك0.8–1.0 mm galvanized external casing sheet
الكثافة الأساسيةApproximately 7850 kg/m³ for the galvanized steel blade bank
الموصلية الحراريةApproximately 45–55 W/(m·K) for the steel airflow components
إنهاء السطحGalvanized casing with corrosion-protected gears, shaft and actuator bracket
نوع المشتركDouble-flanged casing with geared opposed blades, replaceable seals and external direct-coupled actuator
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Analog 0–10 V or digital network controlRoom-pressure or duct-pressure control programAcoustic casing and downstream attenuatorLow-leakage blade seals and spring-return actuator

Planning a Variable Air Volume Control Damper specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat