Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Systèmes de distribution d'air Cleanroom / Variable Air Volume Control Damper
Systèmes de distribution d'air Cleanroom

Amortisseur de contrôle de volume d'air variable Valve de régulation du débit d'air

A sensor-equipped modulating damper that compares measured airflow with a remote setpoint and repositions opposed blades as demand changes.
  • Closed-Loop Airflow Control
  • Averaging Pressure Sensor
  • Modulating Opposed Blades
  • BMS Setpoint Interface
Demander un devis. Browse les produits

Introduction de produit

The variable air volume control damper combines a rectangular galvanized casing, opposed control blades, an averaging differential-pressure sensor and a matched electronic controller-actuator assembly. Pressure measured at several points across the inlet is converted into an airflow signal and compared with the commanded setpoint. The actuator then moves the blade bank until the measured value returns to the required range. Replaceable edge seals and enclosed blade gears support low-leakage shut-off and keep the linkage outside the main airstream.

Key Features

Multi-point effective-pressure sensing averages the inlet profile instead of relying on a single pressure tap.

Opposed airfoil blades provide progressive modulation across a broad minimum-to-maximum airflow range.

The controller can accept an analog or digital setpoint for temperature, occupancy or room-pressure sequences.

External electronics, shaft indication and replaceable seals simplify functional checks without removing the damper.

Préoccupations du client produit

Accurate VAV control depends on a usable sensor signal, stable inlet conditions, correct actuator authority and a minimum airflow that protects the room process.

A single pressure pickup reports an incorrect flow value behind an elbow.An averaging sensor samples several locations and a straight inlet section reduces profile distortion.
The actuator hunts because the controller gain is too aggressive for the duct response.Matched actuator timing and tuned control parameters provide stable movement around the airflow setpoint.
Closing below the validated minimum airflow disrupts room pressure and dilution.Programmable minimum and maximum limits keep the commanded airflow inside the operating envelope.
Blade leakage prevents an unused branch from isolating during setback.Tip and jamb seals combined with opposed blades improve shut-off when the controller receives a close override.

Les applications typiques

Cleanroom supply-air modulationLaboratory room exhaust controlPressure-cascade airflow trackingDemand-controlled pharmaceutical support roomsVariable-volume healthcare ventilation

Paramètres techniques

Typical mechanical construction ranges for a rectangular electronic VAV control damper are listed below.

Matériaux de baseGalvanized-steel opposed control blades with TPE seals and aluminum averaging pressure sensor
Panneau épaisseur0.8–1.5 mm blade and casing components
Largeur effective200–1000 mm nominal rectangular airway width
Longueur maximaleUp to 1200 mm casing length with acoustic cladding or service section
Acier face épaisseur0.8–1.0 mm galvanized external casing sheet
Densité CoreApproximately 7850 kg/m³ for the galvanized steel blade bank
Conductivité thermiqueApproximately 45–55 W/(m·K) for the steel airflow components
surface finieGalvanized casing with corrosion-protected gears, shaft and actuator bracket
Type jointDouble-flanged casing with geared opposed blades, replaceable seals and external direct-coupled actuator
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Analog 0–10 V or digital network controlRoom-pressure or duct-pressure control programAcoustic casing and downstream attenuatorLow-leakage blade seals and spring-return actuator

Planning a Variable Air Volume Control Damper specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact