موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
أنظمة المرافق الغرف النظيفة

فراغ مرشح معقم

A compact full-vacuum sanitary filter that places one hydrophobic 0.2 µm PTFE gas cartridge between a clean process suction line and its vacuum source, helping retain microbial aerosols and particles before they reach the pump.
  • Full-vacuum 316L sanitary housing
  • One hydrophobic 0.2 µm PTFE cartridge
  • 1-inch Tri-Clamp ports with vent and drain
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The Vacuum Sterile Filter is a small suction-line barrier for clean and aseptic utility applications where a vacuum pump must be isolated from process aerosols without using a general-purpose aluminum inlet bowl. The locked configuration pairs one Pall BTS7001G23J-class T-flow Junior housing with one SBF1PFRWH4-class hydrophobic double-layer PTFE cartridge. Its electropolished 316L body is rated for full vacuum, uses two 1-inch sanitary connections, and provides dedicated vent and low-point drain functions around a single replaceable element. The assembly supports controlled in-situ steaming when the selected cartridge, seal and procedure are compatible. It is not a liquid separator, does not create vacuum and does not by itself establish a permanently sterile system.

الخصائص الرئيسية

Full-vacuum housing construction resists atmospheric external pressure on the suction side of the pump

A single pleated double-layer hydrophobic PTFE cartridge provides a defined microbial and particulate barrier for compatible gas service

The compact 64 mm body and 218 mm-class overall height suit point-of-use or skid-mounted vacuum branches

Electropolished 316L wetted surfaces reduce crevices and support hygienic cleaning around the reusable housing

Two 1-inch sanitary Tri-Clamp ferrules avoid the threaded aluminum ports commonly used on ordinary pump inlet filters

A dedicated top vent helps displace trapped gas during wetting or steaming operations

A low-point drain gives condensate a controlled exit after isolation and safe vacuum release

The quick-release closure ring and rear stainless mounting bracket simplify element access while keeping the housing vertical

مخاوف المنتج للعملاء

Vacuum filtration performance depends on line conductance, gas load, moisture carryover, element integrity, steam sequencing and the lowest absolute pressure expected at the housing.

A filter selected from positive-pressure flow data can impose excessive suction loss and reduce vacuum response at the process connectionSize the cartridge from the actual gas throughput, inlet absolute pressure and allowable clean-to-change pressure drop, including the conductance of valves and tubing.
Bulk liquid or foam can wet the membrane, sharply increase resistance and carry contamination toward the vacuum pumpInstall a correctly sized receiver or sanitary knockout stage upstream where liquid carryover is credible, keep the filter vertical and drain the isolated housing at its low point.
A thin housing intended only for internal pressure can deform when its interior is evacuatedUse the documented full-vacuum housing boundary and verify that every valve, gauge blank, clamp, gasket and accessory shares the required vacuum rating.
Trapped air or condensate can prevent uniform steam exposure and leave the cartridge wet after a sterilization cycleUse the dedicated top vent and bottom drain in a defined steam sequence, control differential pressure across the element and allow drying before vacuum service resumes.
Calling an element sterile without an integrity check can hide installation damage, seal bypass or media wettingDefine a compatible integrity-test method and acceptance limit for the selected cartridge, then test at the intervals required by the process control plan.
A terminal exhaust HEPA filter or ordinary dirt-loading inlet filter may be mistaken for a sanitary microbial barrierSpecify the suction-side process boundary, hydrophobic microbially rated cartridge, sanitary full-vacuum housing and steam-compatible arrangement as one matched assembly.

تطبيقات نموذجية

Suction-side protection for vacuum pumps serving aseptic process vesselsBiopharmaceutical vacuum branches exposed to microbial aerosols from sampling or transfer operationsLyophilizer and autoclave vacuum-break or evacuation lines requiring a hydrophobic gas barrierLaboratory and pilot-plant vacuum manifolds handling clean, non-condensing gasesFood and beverage process-vacuum connections where sanitary hardware and steam compatibility are specifiedCleanroom utility skids requiring a compact full-vacuum cartridge housing upstream of the pump

المعلمات الفنية

The locked catalogue-scale identity is one BTS7001G23J-class T-flow Junior sanitary housing fitted with one SBF1PFRWH4-class filter. The housing basis is electropolished 316L stainless steel, approximately 64 mm across the cylindrical body and 218 mm high, with a -1 to 10 barg published pressure envelope, 140°C housing steam-temperature limit, one closure ring, two 1-inch sanitary ferrules, one top vent, one bottom drain and one rear mounting bracket. The element basis is one compact single-open-end cartridge with 410 cm² of pleated double-layer hydrophobic 0.2 µm PTFE media and a silicone seal. Full-vacuum compatibility belongs to the selected housing; microbial retention, steam life and integrity limits belong to the selected element and must be applied at the actual operating conditions.

المواد الأساسيةOne pleated double-layer hydrophobic 0.2 µm PTFE membrane cartridge with polypropylene support hardware and a silicone elastomer seal
سمك اللوحة1.5-2.0 mm representative formed 316L cylindrical housing wall basis for this compact single-element scale
العرض الفعال64 mm nominal cylindrical housing width excluding sanitary ferrules and mounting bracket
الحد الأقصى الطول218 mm nominal assembled height for the selected T-flow Junior housing
الصلب يواجه سمك1.5 mm representative 316L sanitary ferrule and closure-component wall basis
الكثافة الأساسيةApproximately 2160 kg/m³ for the solid PTFE polymer reference; the porous pleated cartridge has a lower effective bulk density
الموصلية الحراريةApproximately 0.24 W/(m·K) representative of solid unfilled PTFE near ambient temperature
إنهاء السطحNatural bright-silver electropolished 316L housing with a crevice-minimized sanitary interior and dark silicone sealing points
نوع المشتركTwo opposed 1-inch sanitary Tri-Clamp ferrules, one quick-release body closure ring, one top vent, one bottom drain and one single SBF-style cartridge seat
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Alternative hydrophobic PTFE or hydrophobic depth-media cartridge selected for gas chemistry and pressure-drop targetDifferent compact cartridge lengths and filtration areas for the required vacuum throughputSanitary clamp or weld-end process connections matched to the clean utility lineSilicone, EPDM or compatible fluoropolymer seal optionsTop vent and low-point drain valve styles suited to manual or automated steam sequencingIntegrity-test connection and compatible test equipment interfaceNatural stainless wall bracket or skid-mount support geometryUpstream sanitary knock-out pot or receiver for applications with credible liquid carryover

Planning a Vacuum Sterile Filter specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا