Glove اختبار النزاهة
- In-situ pressure-decay testing.
- Single glove-port workflow.
- Traceable curve and result capture.
مقدمة المنتج
This compact single-channel tester combines a controlled inflation path, pressure sensing, timing and curve display in one portable console. A dedicated round adapter seals against the selected isolator or RABS glove port while the installed glove and sleeve remain in place. The instrument raises the assembly to the configured test pressure, allows a defined stabilization period, isolates the air supply and records pressure change over the measurement interval. The resulting curve and numerical decay value can be compared with an established recipe for that glove material, size, port geometry and environmental condition. A displayed result is test evidence; it does not by itself certify the barrier or replace the site's approved integrity procedure and visual inspection.
الخصائص الرئيسية
Color touch display presents inflation, stabilization and pressure-decay phases as one time-based curve for immediate review.
Four physical keys provide essential start, stop, navigation and confirmation control when touchscreen-only operation is undesirable.
Matched round port cover with a replaceable hygienic seal supports in-situ testing without removing the glove or sleeve from its working flange.
One regulated pneumatic path, one pressure sensor and a quick coupling simplify setup checks and help preserve repeatable test conditions.
Rechargeable battery base and integrated top handle support movement between glove ports without a permanently installed console.
مخاوف المنتج للعملاء
Meaningful glove integrity testing depends on more than measuring a pressure drop: the port-cover seal, glove elasticity, temperature, stabilization interval, test pressure and acceptance threshold must all be controlled for the specific glove-and-sleeve assembly.
تطبيقات نموذجية
المعلمات الفنية
The representative portable system below provides one regulated pressure-decay channel, one matched glove-port adapter and time-based result capture. Final pressure range, stabilization time, measurement duration, adapter diameter, seal material and recipe limits should be selected for the intended glove assembly and test procedure.
| المواد الأساسية | Powder-coated aluminum portable chassis with PC/ABS blue protective trim, stainless or engineering-polymer glove-port adapter, silicone sealing ring and clean pneumatic tubing |
|---|---|
| سمك اللوحة | Typically 2.0-3.0 mm for the portable enclosure panels and protective trim sections |
| العرض الفعال | Approximately 280-360 mm across the main tester console, excluding the detached glove-port adapter |
| الحد الأقصى الطول | Approximately 650-900 mm for the complete arranged kit including the connected hose, adapter and one installed glove |
| الصلب يواجه سمك | Typically 1.0-1.5 mm for stainless adapter covers, connector plates and protective hardware |
| الكثافة الأساسية | Approximately 2700 kg/m³ for the aluminum structural chassis sections |
| الموصلية الحرارية | Approximately 160-205 W/(m·K) for the aluminum chassis alloy |
| إنهاء السطح | Smooth warm-white and light-gray enclosure with cobalt-blue protective trim, dark touch display, charcoal keys, satin stainless fittings, blue pneumatic tube and a light-blue glove sample |
| نوع المشترك | Single regulated console outlet with one stainless quick coupling and blue pneumatic hose to one round glove-port test adapter with a replaceable compression seal |
| التخصيص | متوفر على أساس التطبيق المقصود وبيئة التشغيل. |
الخيارات المتاحة