Prueba de integridad Glove
- In-situ pressure-decay testing.
- Single glove-port workflow.
- Traceable curve and result capture.
Introducción del producto
This compact single-channel tester combines a controlled inflation path, pressure sensing, timing and curve display in one portable console. A dedicated round adapter seals against the selected isolator or RABS glove port while the installed glove and sleeve remain in place. The instrument raises the assembly to the configured test pressure, allows a defined stabilization period, isolates the air supply and records pressure change over the measurement interval. The resulting curve and numerical decay value can be compared with an established recipe for that glove material, size, port geometry and environmental condition. A displayed result is test evidence; it does not by itself certify the barrier or replace the site's approved integrity procedure and visual inspection.
Características clave
Color touch display presents inflation, stabilization and pressure-decay phases as one time-based curve for immediate review.
Four physical keys provide essential start, stop, navigation and confirmation control when touchscreen-only operation is undesirable.
Matched round port cover with a replaceable hygienic seal supports in-situ testing without removing the glove or sleeve from its working flange.
One regulated pneumatic path, one pressure sensor and a quick coupling simplify setup checks and help preserve repeatable test conditions.
Rechargeable battery base and integrated top handle support movement between glove ports without a permanently installed console.
Preocupaciones del producto del cliente
Meaningful glove integrity testing depends on more than measuring a pressure drop: the port-cover seal, glove elasticity, temperature, stabilization interval, test pressure and acceptance threshold must all be controlled for the specific glove-and-sleeve assembly.
Aplicaciones típicas
Parámetros técnicos
The representative portable system below provides one regulated pressure-decay channel, one matched glove-port adapter and time-based result capture. Final pressure range, stabilization time, measurement duration, adapter diameter, seal material and recipe limits should be selected for the intended glove assembly and test procedure.
| Materiales Core | Powder-coated aluminum portable chassis with PC/ABS blue protective trim, stainless or engineering-polymer glove-port adapter, silicone sealing ring and clean pneumatic tubing |
|---|---|
| Panel de espesor | Typically 2.0-3.0 mm for the portable enclosure panels and protective trim sections |
| Ancho efectivo | Approximately 280-360 mm across the main tester console, excluding the detached glove-port adapter |
| Longitud máxima | Approximately 650-900 mm for the complete arranged kit including the connected hose, adapter and one installed glove |
| Acero frente a espesor | Typically 1.0-1.5 mm for stainless adapter covers, connector plates and protective hardware |
| Densidad Core | Approximately 2700 kg/m³ for the aluminum structural chassis sections |
| Conductividad térmica | Approximately 160-205 W/(m·K) for the aluminum chassis alloy |
| Superficie acabada | Smooth warm-white and light-gray enclosure with cobalt-blue protective trim, dark touch display, charcoal keys, satin stainless fittings, blue pneumatic tube and a light-blue glove sample |
| Tipo conjunto | Single regulated console outlet with one stainless quick coupling and blue pneumatic hose to one round glove-port test adapter with a replaceable compression seal |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Glove Integrity Tester specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.