Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Temiz Oda Kontrolü ve Çevre İzleme Sistemleri

Çevresel İzleme Sistemi

A continuous monitoring platform that acquires cleanroom pressure, temperature, humidity, particle and utility-status signals for centralized alarming and records.
  • Continuous Multi-Parameter Capture
  • Distributed Data Loggers
  • Excursion Alarms
  • Central Trend Records
Alıntı isteği Browse ürünleri

Ürün tanıtımı

This monitoring system is independent of routine HVAC control and concentrates on trustworthy acquisition, local buffering and clear exception reporting. Distributed loggers receive digital sensors, analog transmitters and door contacts, then forward time-stamped measurements to the monitoring server. Local memory preserves readings during network interruptions, while configurable alarm delays reduce nuisance notifications caused by brief door movement. The platform presents room dashboards, trends and scheduled reports for cleanrooms, storage areas and supporting utilities.

Ana Özellikler

Distributed loggers collect mixed measurement types close to the monitored rooms.

Local memory protects measurement continuity when network communication is interrupted.

Independent alarm limits, delays and notification paths can be assigned to each parameter.

Central dashboards compare live status, historical trends and acknowledged excursion events.

Müşteri Ürün Sorunları

Environmental records must remain continuous and understandable even when sensors, network links and room activities change independently.

A network outage creates gaps in critical environmental records.Data loggers buffer measurements locally and backfill the server after communication returns.
Short door openings trigger repeated nuisance alarms.Per-parameter delay and deadband settings distinguish brief disturbances from sustained excursions.
Different sensor types cannot share one monitoring platform.Analog, digital, Modbus and dry-contact inputs accept mixed field instrumentation.
Staff cannot quickly identify which room requires attention.Color-coded floor and room views prioritize active alarms and show the responsible parameter.

Tipik uygulamalar

GMP cleanroom monitoringControlled storage suitesLaboratory environmental recordsMulti-room critical facilities

Teknik parametreler

Typical enclosure construction for a distributed cleanroom environmental monitoring panel is listed below.

Temel malzemelerPowder-coated steel enclosure with FR-4 acquisition boards and isolated signal-conditioning modules
Panel kalınlığı180-300 mm enclosure depth
Effective Width (Etkili Genişlik)500-1000 mm panel width
Maksimum uzunlukUp to 1800 mm panel height
Çelik yüz yüze kalınlığı1.2-1.8 mm powder-coated steel panels
Core Density (Çekirdek Yoğunluğu)7800-8050 kg/m³ for steel enclosure parts
Termal İletkenlik45-60 W/(m·K) for the steel enclosure
Yüzey bitirmeSmooth light-gray powder coat with engraved channel and alarm labels
Ortak tipGasketed wall or floor cabinet with pluggable I/O terminals and network isolation sections
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Wired or wireless data loggersSMS and email alarm routingRedundant database storageOPC UA and API integration

Planning a Environmental Monitoring System specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat