Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Systèmes de contrôle des salles blanches et de surveillance environnementale

Système de surveillance environnementale

A continuous monitoring platform that acquires cleanroom pressure, temperature, humidity, particle and utility-status signals for centralized alarming and records.
  • Continuous Multi-Parameter Capture
  • Distributed Data Loggers
  • Excursion Alarms
  • Central Trend Records
Demander un devis. Browse les produits

Introduction de produit

This monitoring system is independent of routine HVAC control and concentrates on trustworthy acquisition, local buffering and clear exception reporting. Distributed loggers receive digital sensors, analog transmitters and door contacts, then forward time-stamped measurements to the monitoring server. Local memory preserves readings during network interruptions, while configurable alarm delays reduce nuisance notifications caused by brief door movement. The platform presents room dashboards, trends and scheduled reports for cleanrooms, storage areas and supporting utilities.

Key Features

Distributed loggers collect mixed measurement types close to the monitored rooms.

Local memory protects measurement continuity when network communication is interrupted.

Independent alarm limits, delays and notification paths can be assigned to each parameter.

Central dashboards compare live status, historical trends and acknowledged excursion events.

Préoccupations du client produit

Environmental records must remain continuous and understandable even when sensors, network links and room activities change independently.

A network outage creates gaps in critical environmental records.Data loggers buffer measurements locally and backfill the server after communication returns.
Short door openings trigger repeated nuisance alarms.Per-parameter delay and deadband settings distinguish brief disturbances from sustained excursions.
Different sensor types cannot share one monitoring platform.Analog, digital, Modbus and dry-contact inputs accept mixed field instrumentation.
Staff cannot quickly identify which room requires attention.Color-coded floor and room views prioritize active alarms and show the responsible parameter.

Les applications typiques

GMP cleanroom monitoringControlled storage suitesLaboratory environmental recordsMulti-room critical facilities

Paramètres techniques

Typical enclosure construction for a distributed cleanroom environmental monitoring panel is listed below.

Matériaux de basePowder-coated steel enclosure with FR-4 acquisition boards and isolated signal-conditioning modules
Panneau épaisseur180-300 mm enclosure depth
Largeur effective500-1000 mm panel width
Longueur maximaleUp to 1800 mm panel height
Acier face épaisseur1.2-1.8 mm powder-coated steel panels
Densité Core7800-8050 kg/m³ for steel enclosure parts
Conductivité thermique45-60 W/(m·K) for the steel enclosure
surface finieSmooth light-gray powder coat with engraved channel and alarm labels
Type jointGasketed wall or floor cabinet with pluggable I/O terminals and network isolation sections
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Wired or wireless data loggersSMS and email alarm routingRedundant database storageOPC UA and API integration

Planning a Environmental Monitoring System specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat