Temiz Odası Kapı Kilitleme Kontrolörü

A central low-voltage controller for cleanroom airlocks, coordinating door-position inputs, electric locks, request devices, status indicators, alarms and emergency release functions.
  • Configurable Door Logic
  • Labeled Lock and Sensor I/O
  • Alarm and Emergency Inputs
  • Access-Control Integration
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The cleanroom door interlock controller is the logic hub behind a personnel or material airlock. It reads each door-position contact, determines whether another opening request is permitted and controls the corresponding electromagnetic lock or electric strike. A serviceable enclosure contains the power supply, protected output circuits, labeled terminals and programmable logic. Interface contacts can exchange status or release commands with access control, fire alarm and building-management systems without placing exposed electronics in the cleanroom doorway.

Ana Özellikler

Dedicated inputs distinguish door-closed feedback, opening requests and emergency release commands.

Protected lock outputs support common fail-safe or fail-secure electric-lock arrangements.

Adjustable door-open and air-purge delays accommodate different airlock operating sequences.

Dry-contact interfaces allow coordinated signals with access control, fire alarm and BMS equipment.

Müşteri Ürün Sorunları

A controller must make door state visible, release locks safely and avoid ambiguous field wiring while remaining flexible enough for different airlock sequences.

A controller releases a second door because it cannot confirm that the first door is fully closed.Independent door-position inputs are evaluated before every release output is enabled.
Unlabeled field terminals make service faults difficult to isolate.Grouped and clearly identified inputs, lock outputs and auxiliary contacts simplify tracing and replacement.
A rigid sequence cannot accommodate purge time or emergency egress requirements.Configurable timers and dedicated emergency/fire inputs separate normal operating logic from safety release behavior.

Tipik uygulamalar

Personnel airlocksMaterial airlocksCleanroom gowning suitesLaboratory containment entrances

Teknik parametreler

Typical controller enclosure and low-voltage interface ranges are listed below.

Temel malzemelerIndustrial control PCB, protected relay outputs and regulated low-voltage power supply in a service enclosure
Panel kalınlığı80–130 mm enclosure depth
Effective Width (Etkili Genişlik)200–300 mm enclosure width
Maksimum uzunluk350 mm enclosure height
Çelik yüz yüze kalınlığı1.0–1.5 mm powder-coated steel enclosure; polycarbonate enclosure optional
Core Density (Çekirdek Yoğunluğu)Approximately 1800–1920 kg/m³ for the glass-reinforced PCB laminate
Termal İletkenlikApproximately 0.4–0.7 W/(m·K) for the PCB laminate used inside the controller
Yüzey bitirmePowder-coated steel or smooth sealed polycarbonate enclosure with labeled internal terminals
Ortak tipDIN-rail and PCB terminal connections for door contacts, locks, request buttons and auxiliary dry contacts
Customization (Özelleşme)Kullanılan amaçlanan uygulama ve çalışma ortamına göre kullanılabilir

Mevcut Seçenekler

12 or 24 VDC lock circuitsFail-safe or fail-secure logicDoor-open alarm and purge timerFire alarm, BMS and access-control interfaces