Sanfürifü Temiz Oda Egzoz Hava Fan Unit
- Stable Negative-Pressure Exhaust
- Sealed Service Cabinet
- Backward-Curved Centrifugal Wheel
- Isolated Inline Installation
Ürün tanıtımı
The cleanroom exhaust-air fan unit encloses a centrifugal wheel, motor, isolation base and pressure connections in a gasketed steel cabinet. Its backward-curved impeller develops the static pressure needed for terminal filters, control dampers and long duct routes while keeping the motor accessible from the side. A direct-drive EC or belt-drive arrangement can be selected to match airflow range, service policy and discharge temperature.
Ana Özellikler
Gasketed access panels limit uncontrolled air leakage that would otherwise reduce extraction at the room terminal.
An isolated motor and wheel assembly prevents rotating vibration from entering the exhaust duct and building structure.
Pressure taps and speed control allow the fan to maintain duct suction as filters or dampers change resistance.
Müşteri Ürün Sorunları
Containment exhaust must maintain reliable suction through changing filter resistance without leaking contaminated air into the technical space.
Tipik uygulamalar
Teknik parametreler
Typical structural ranges for an insulated centrifugal cleanroom exhaust-air fan cabinet are listed below.
| Temel malzemeler | Backward-curved aluminum or coated-steel wheel in a mineral-wool-lined galvanized steel exhaust cabinet |
|---|---|
| Panel kalınlığı | 25-50 mm insulated double-skin cabinet panel thickness |
| Effective Width (Etkili Genişlik) | 500-1800 mm nominal exhaust-fan cabinet width |
| Maksimum uzunluk | Up to 2400 mm overall cabinet length including inlet and discharge collars |
| Çelik yüz yüze kalınlığı | 0.8-1.5 mm galvanized or coated steel casing sheet |
| Core Density (Çekirdek Yoğunluğu) | 40-80 kg/m³ typical mineral-wool acoustic and thermal lining density |
| Termal İletkenlik | Approximately 0.035-0.045 W/(m·K) for mineral-wool cabinet lining |
| Yüzey bitirme | White powder-coated exterior with blue gasketed service door and corrosion-resistant internal surfaces |
| Ortak tip | Bolted sealed cabinet with flanged duct collars, flexible connectors and vibration-isolated fan base |
| Customization (Özelleşme) | Kullanılan uygulama ve çalışma ortamına göre kullanılabilir. |
Mevcut Seçenekler
Planning a Centrifugal Cleanroom Exhaust-Air Fan Unit specification?
Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.