Unidad de filtro de ventilador de bajo ruido
- Acoustic-Lined Pressure Plenum
- Elastomeric Motor Isolation
- Low-Turbulence Inlet Bell
- Quiet Variable-Speed EC Drive
Introducción del producto
The low-noise fan filter unit controls airborne and structure-borne sound at their main sources. A backward-curved EC fan sits on elastomeric isolators, while a smooth inlet bell reduces separation noise entering the wheel. Selected interior surfaces carry cleanable encapsulated acoustic lining, and the outlet baffle moderates local velocity peaks before the final filter. The result is intended for continuously occupied rooms where speech, concentration and operator comfort matter alongside particulate control.
Características clave
A radiused intake bell lowers inlet turbulence and the broadband noise associated with a sharp-edged opening.
Encapsulated acoustic lining absorbs internal fan noise without exposing loose fibers to the clean-air path.
Continuous EC speed control allows the unit to operate at the lowest practical rotational speed for the required airflow.
Preocupaciones del producto del cliente
A quiet FFU must reduce fan and vibration noise without placing porous or shedding materials in the downstream clean-air path.
Aplicaciones típicas
Parámetros técnicos
Typical materials and dimensional ranges for an acoustically treated low-noise fan filter unit are shown below.
| Materiales Core | Powder-coated steel plenum, isolated EC centrifugal fan, encapsulated acoustic liner and HEPA or ULPA filter pack |
|---|---|
| Panel de espesor | 300-420 mm overall module depth |
| Ancho efectivo | 575-1170 mm nominal ceiling-grid width |
| Longitud máxima | Up to 1170 mm standard module length |
| Acero frente a espesor | 0.8-1.2 mm formed steel housing and perforated acoustic-liner facing |
| Densidad Core | Approximately 24-40 kg/m³ nominal density of the encapsulated acoustic liner |
| Conductividad térmica | Approximately 0.032-0.040 W/(m·K) for the dry acoustic-liner material |
| Superficie acabada | White low-gloss powder coating with sealed dark acoustic lining confined to the upstream plenum |
| Tipo conjunto | Vibration-isolated drop-in flange with closed-cell ceiling gasket and compression-sealed filter frame |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Low-Noise Fan Filter Unit specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita