A quiet EC-powered FFU that combines motor isolation, a rounded inlet and an acoustic-lined plenum to reduce tonal noise above occupied cleanroom work areas.
  • Acoustic-Lined Pressure Plenum
  • Elastomeric Motor Isolation
  • Low-Turbulence Inlet Bell
  • Quiet Variable-Speed EC Drive
見積もりリクエスト 製品案内

商品紹介

The low-noise fan filter unit controls airborne and structure-borne sound at their main sources. A backward-curved EC fan sits on elastomeric isolators, while a smooth inlet bell reduces separation noise entering the wheel. Selected interior surfaces carry cleanable encapsulated acoustic lining, and the outlet baffle moderates local velocity peaks before the final filter. The result is intended for continuously occupied rooms where speech, concentration and operator comfort matter alongside particulate control.

主要な特徴

Elastomeric fan mounts reduce the vibration transferred from the rotating assembly into the plenum and ceiling grid.

A radiused intake bell lowers inlet turbulence and the broadband noise associated with a sharp-edged opening.

Encapsulated acoustic lining absorbs internal fan noise without exposing loose fibers to the clean-air path.

Continuous EC speed control allows the unit to operate at the lowest practical rotational speed for the required airflow.

お客様の製品に関する懸念事項

A quiet FFU must reduce fan and vibration noise without placing porous or shedding materials in the downstream clean-air path.

A tonal motor sound becomes tiring when operators work directly below FFUs for a full shift.The EC motor, rounded inlet and optimized backward-curved wheel reduce the dominant rotating and inlet tones.
Fan vibration travels through a rigid casing and turns the suspended ceiling into a sounding board.Elastomeric mounts interrupt the structural transmission path between the fan and the module frame.
Unprotected fibrous acoustic foam could shed particles into the clean airflow.The selected sound-absorbing liner is sealed behind a cleanable perforated facing on the upstream plenum surfaces.
A unit selected at maximum speed remains unnecessarily loud after room balancing.Variable EC control lets each module run only fast enough to meet the measured airflow setpoint.

典型的な用途

Pharmaceutical inspection roomsClean laboratories with seated operatorsMedical-device assembly areasHospital pharmacy cleanroomsMetrology and optical inspection spaces

技術的なパラメータ

Typical materials and dimensional ranges for an acoustically treated low-noise fan filter unit are shown below.

コア材料Powder-coated steel plenum, isolated EC centrifugal fan, encapsulated acoustic liner and HEPA or ULPA filter pack
パネルの厚さ300-420 mm overall module depth
有効幅575 — 1170 mm 公称天井グリッド幅
最大長さ最大 1170 mm 標準モジュール長
鋼鉄の厚さを直面する0.8-1.2 mm formed steel housing and perforated acoustic-liner facing
コア密度Approximately 24-40 kg/m³ nominal density of the encapsulated acoustic liner
熱伝導率Approximately 0.032-0.040 W/(m·K) for the dry acoustic-liner material
表面仕上げWhite low-gloss powder coating with sealed dark acoustic lining confined to the upstream plenum
ジョイントタイプVibration-isolated drop-in flange with closed-cell ceiling gasket and compression-sealed filter frame
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。