Low-Noise - Fan-Filter Einheit
- Acoustic-Lined Pressure Plenum
- Elastomeric Motor Isolation
- Low-Turbulence Inlet Bell
- Quiet Variable-Speed EC Drive
Produkteinführung
The low-noise fan filter unit controls airborne and structure-borne sound at their main sources. A backward-curved EC fan sits on elastomeric isolators, while a smooth inlet bell reduces separation noise entering the wheel. Selected interior surfaces carry cleanable encapsulated acoustic lining, and the outlet baffle moderates local velocity peaks before the final filter. The result is intended for continuously occupied rooms where speech, concentration and operator comfort matter alongside particulate control.
Key Features
A radiused intake bell lowers inlet turbulence and the broadband noise associated with a sharp-edged opening.
Encapsulated acoustic lining absorbs internal fan noise without exposing loose fibers to the clean-air path.
Continuous EC speed control allows the unit to operate at the lowest practical rotational speed for the required airflow.
Kunden Produktbedenken
A quiet FFU must reduce fan and vibration noise without placing porous or shedding materials in the downstream clean-air path.
Typische Anwendungen
Technische Parameter
Typical materials and dimensional ranges for an acoustically treated low-noise fan filter unit are shown below.
| Core Material | Powder-coated steel plenum, isolated EC centrifugal fan, encapsulated acoustic liner and HEPA or ULPA filter pack |
|---|---|
| Panel Dicke | 300-420 mm overall module depth |
| Effektive Breite | 575 - 1170 mm Nenndecken-Gitterbreite |
| Maximale Länge | Bis zu 1170 mm Standardmodullänge |
| Stahl facing Dicke | 0.8-1.2 mm formed steel housing and perforated acoustic-liner facing |
| Kerndichte | Approximately 24-40 kg/m³ nominal density of the encapsulated acoustic liner |
| Thermische Leitfähigkeit | Approximately 0.032-0.040 W/(m·K) for the dry acoustic-liner material |
| Oberfläche Finish | White low-gloss powder coating with sealed dark acoustic lining confined to the upstream plenum |
| Gemeinsamer Typ | Vibration-isolated drop-in flange with closed-cell ceiling gasket and compression-sealed filter frame |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Low-Noise Fan Filter Unit specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Englisch
DeutschCurrent
Arabisch
Französisch
indonesisch
Japanisch
Koreanisch
Malaiisch
Portugiesisch
Russisch
Spanisch
Thailändisch
Türkischer Sprache
Vietnamesisch