Unité de filtre à ventilateur à faible bruit
- Acoustic-Lined Pressure Plenum
- Elastomeric Motor Isolation
- Low-Turbulence Inlet Bell
- Quiet Variable-Speed EC Drive
Introduction de produit
The low-noise fan filter unit controls airborne and structure-borne sound at their main sources. A backward-curved EC fan sits on elastomeric isolators, while a smooth inlet bell reduces separation noise entering the wheel. Selected interior surfaces carry cleanable encapsulated acoustic lining, and the outlet baffle moderates local velocity peaks before the final filter. The result is intended for continuously occupied rooms where speech, concentration and operator comfort matter alongside particulate control.
Key Features
A radiused intake bell lowers inlet turbulence and the broadband noise associated with a sharp-edged opening.
Encapsulated acoustic lining absorbs internal fan noise without exposing loose fibers to the clean-air path.
Continuous EC speed control allows the unit to operate at the lowest practical rotational speed for the required airflow.
Préoccupations du client produit
A quiet FFU must reduce fan and vibration noise without placing porous or shedding materials in the downstream clean-air path.
Les applications typiques
Paramètres techniques
Typical materials and dimensional ranges for an acoustically treated low-noise fan filter unit are shown below.
| Matériaux de base | Powder-coated steel plenum, isolated EC centrifugal fan, encapsulated acoustic liner and HEPA or ULPA filter pack |
|---|---|
| Panneau épaisseur | 300-420 mm overall module depth |
| Largeur effective | 575 - 1170 mm Largeur nominale de grille de plafond par |
| Longueur maximale | Jusqu'à 1170 mm de longueur standard du module par |
| Acier face épaisseur | 0.8-1.2 mm formed steel housing and perforated acoustic-liner facing |
| Densité Core | Approximately 24-40 kg/m³ nominal density of the encapsulated acoustic liner |
| Conductivité thermique | Approximately 0.032-0.040 W/(m·K) for the dry acoustic-liner material |
| surface finie | White low-gloss powder coating with sealed dark acoustic lining confined to the upstream plenum |
| Type joint | Vibration-isolated drop-in flange with closed-cell ceiling gasket and compression-sealed filter frame |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Low-Noise Fan Filter Unit specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien