Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Equipos de HVAC y manejo de aire para salas limpias

Z Coil de enfriamiento de expansión directa por

A direct-expansion evaporator coil that boils refrigerant inside multiple copper circuits to cool and dehumidify cleanroom air.
  • Multi-Circuit Refrigerant Distribution
  • Direct Evaporative Cooling
  • Large Suction Header
  • Matched Condensing Unit Service
Solicite un presupuesto. Browse productos

Introducción del producto

Liquid refrigerant enters a brass distributor and divides through small feeder tubes into multiple copper circuits. It evaporates as air crosses the fin pack, then returns through a large suction header to the remote condensing unit. Distributor sizing, circuit length and coil orientation are coordinated to keep all rows active across the expected load range and to return oil reliably.

Características clave

A precision distributor divides two-phase refrigerant among equalized evaporator circuits.

Copper circuits and aluminum fins provide direct sensible and latent cooling without a secondary water loop.

A large suction header collects vapor at controlled velocity for stable superheat and oil return.

Independent or intertwined circuits can support staged compressors and part-load face coverage.

Preocupaciones del producto del cliente

DX coils depend on uniform refrigerant distribution and correctly matched circuits to prevent starving, flooding and temperature streaks.

Unequal feeder flow leaves some coil circuits inactive.A matched distributor and equal-length feeder tubes divide refrigerant across every circuit.
Low load causes unstable superheat and liquid carryover.Staged or intertwined circuits preserve active face area and stable expansion-valve control.
Long suction runs fail to return compressor oil.Header diameter, circuit velocity and piping traps are selected around the remote condensing unit.
Condensate carryover wets downstream filters.Coil face velocity, fin treatment and drain-pan geometry are coordinated for complete drainage.

Aplicaciones típicas

Remote-DX cleanroom air handlersPackaged make-up air unitsLaboratory environmental chambersMedical manufacturing HVACDedicated humidity-control systems

Parámetros técnicos

Representative construction ranges for a multi-circuit cleanroom DX evaporator coil are listed below.

Materiales CoreC12200 copper refrigerant tubes with aluminum fins, brass distributor and copper suction header
Panel de espesor1.5-2.0 mm galvanized or stainless casing
Ancho efectivo400-2800 mm active fin face width
Longitud máximaUp to 4000 mm overall coil casing length
Acero frente a espesor1.0-1.5 mm stainless drain pan where supplied
Densidad CoreApproximately 8940 kg/m³ for the C12200 copper refrigerant-tube circuit
Conductividad térmicaApproximately 339 W/(m·K) for the C12200 copper DX refrigerant tubes at room temperature
Superficie acabadaNatural, blue hydrophilic or epoxy-coated aluminum fins
Tipo conjuntoBrazed copper refrigerant circuits with flared or brazed distributor and suction connections
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Single, staged or intertwined refrigerant circuitsDifferent tube diameters and row countsHydrophilic or epoxy-coated finsStainless casing, drain pan and moisture eliminator

Planning a Direct-Expansion Cooling Coil specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat

Inicio

Productos

Noticias

Nosotros

Contacto