Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Salle blanche HVAC et équipement de manutention de l'air

Bobine de refroidissement à extension directe

A direct-expansion evaporator coil that boils refrigerant inside multiple copper circuits to cool and dehumidify cleanroom air.
  • Multi-Circuit Refrigerant Distribution
  • Direct Evaporative Cooling
  • Large Suction Header
  • Matched Condensing Unit Service
Demander un devis. Browse les produits

Introduction de produit

Liquid refrigerant enters a brass distributor and divides through small feeder tubes into multiple copper circuits. It evaporates as air crosses the fin pack, then returns through a large suction header to the remote condensing unit. Distributor sizing, circuit length and coil orientation are coordinated to keep all rows active across the expected load range and to return oil reliably.

Key Features

A precision distributor divides two-phase refrigerant among equalized evaporator circuits.

Copper circuits and aluminum fins provide direct sensible and latent cooling without a secondary water loop.

A large suction header collects vapor at controlled velocity for stable superheat and oil return.

Independent or intertwined circuits can support staged compressors and part-load face coverage.

Préoccupations du client produit

DX coils depend on uniform refrigerant distribution and correctly matched circuits to prevent starving, flooding and temperature streaks.

Unequal feeder flow leaves some coil circuits inactive.A matched distributor and equal-length feeder tubes divide refrigerant across every circuit.
Low load causes unstable superheat and liquid carryover.Staged or intertwined circuits preserve active face area and stable expansion-valve control.
Long suction runs fail to return compressor oil.Header diameter, circuit velocity and piping traps are selected around the remote condensing unit.
Condensate carryover wets downstream filters.Coil face velocity, fin treatment and drain-pan geometry are coordinated for complete drainage.

Les applications typiques

Remote-DX cleanroom air handlersPackaged make-up air unitsLaboratory environmental chambersMedical manufacturing HVACDedicated humidity-control systems

Paramètres techniques

Representative construction ranges for a multi-circuit cleanroom DX evaporator coil are listed below.

Matériaux de baseC12200 copper refrigerant tubes with aluminum fins, brass distributor and copper suction header
Panneau épaisseur1.5-2.0 mm galvanized or stainless casing
Largeur effective400-2800 mm active fin face width
Longueur maximaleUp to 4000 mm overall coil casing length
Acier face épaisseur1.0-1.5 mm stainless drain pan where supplied
Densité CoreApproximately 8940 kg/m³ for the C12200 copper refrigerant-tube circuit
Conductivité thermiqueApproximately 339 W/(m·K) for the C12200 copper DX refrigerant tubes at room temperature
surface finieNatural, blue hydrophilic or epoxy-coated aluminum fins
Type jointBrazed copper refrigerant circuits with flared or brazed distributor and suction connections
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Single, staged or intertwined refrigerant circuitsDifferent tube diameters and row countsHydrophilic or epoxy-coated finsStainless casing, drain pan and moisture eliminator

Planning a Direct-Expansion Cooling Coil specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact