ОВК и оборудование для обработки воздуха в чистых помещениях

Оборудование для обработки рециркуляционного воздуха

A high-volume return-air unit that recirculates filtered cleanroom air while handling sensible load and maintaining stable airflow.
  • High Recirculation Airflow
  • Low Fan Energy Path
  • Stable Sensible Cooling
  • Variable-Speed Air Volume
Запрос котировки Просмотреть продукты

Введение продукции

The recirculation air handling unit moves the high air volume needed for particle dilution without repeatedly conditioning the entire stream as outdoor air. Return air passes through accessible filters, a cooling or trim coil and direct-drive fans before returning to ceiling filters or supply distribution. Fresh conditioned air can enter upstream as a smaller measured quantity. Large coil face area and low-pressure-drop components reduce fan energy, while airflow control compensates for terminal filter loading and operating mode changes.

Основные характеристики

Large filter and coil face areas keep pressure drop low across the high recirculation volume.

A small conditioned fresh-air connection can be mixed with the return stream without oversizing the outdoor-air unit.

Direct-drive fan arrays provide turndown and service redundancy for continuous production areas.

Sensible trim cooling removes room and fan heat without duplicating full latent treatment.

Обеспокоенность клиентов продуктами

High cleanroom air-change rates magnify every unnecessary filter, coil and duct pressure loss in the recirculation path.

A small coil and filter bank create excessive fan energy at high recirculation volume.Expanded face area lowers component velocity and reduces pressure drop.
Terminal filter loading gradually reduces cleanroom air changes.Variable-speed fans maintain the scheduled airflow or duct static-pressure setpoint.
One large fan failure stops production airflow.A multi-fan array can continue at reduced capacity while one fan position is isolated.
Mixing humid outdoor air into the return stream destabilizes room moisture.A separate conditioned fresh-air connection introduces air at a controlled dew point.

Типичные приложения

Large pharmaceutical cleanroomsSemiconductor clean productionMedical-device assembly hallsBattery manufacturing clean zonesHigh-air-change laboratories

Технические параметры

The following ranges describe a high-volume cleanroom recirculation AHU casing.

Основной материалPolyurethane or high-density mineral-wool acoustic and thermal panel insulation
Толщина панели50–60 mm double-skin casing
эффективная ширина1200–4200 mm nominal casing width
Максимальная длинаUp to 9000 mm for filters, coil, fan array and mixing section
Толщина линий стали0.6–1.0 mm galvanized or coated casing skins
Плотность ядра42–45 kg/m³ polyurethane or 80–110 kg/m³ mineral wool
Теплопроводимость0.022–0.040 W/(m·K) depending on panel core
Поверхностная отделкаPowder-coated outer skin with smooth galvanized or coated inner skin
Объединенный типGasketed low-leakage panel joints and bolted modular fan/coil sections
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

EC fan wall with N+1 fan positionChilled-water or refrigerant trim coilReturn prefilter or fine-filter bankTop, side or end return and supply connections