Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Salle blanche HVAC et équipement de manutention de l'air

Unité de traitement de l'air de recirculation

A high-volume return-air unit that recirculates filtered cleanroom air while handling sensible load and maintaining stable airflow.
  • High Recirculation Airflow
  • Low Fan Energy Path
  • Stable Sensible Cooling
  • Variable-Speed Air Volume
Demander un devis. Browse les produits

Introduction de produit

The recirculation air handling unit moves the high air volume needed for particle dilution without repeatedly conditioning the entire stream as outdoor air. Return air passes through accessible filters, a cooling or trim coil and direct-drive fans before returning to ceiling filters or supply distribution. Fresh conditioned air can enter upstream as a smaller measured quantity. Large coil face area and low-pressure-drop components reduce fan energy, while airflow control compensates for terminal filter loading and operating mode changes.

Key Features

Large filter and coil face areas keep pressure drop low across the high recirculation volume.

A small conditioned fresh-air connection can be mixed with the return stream without oversizing the outdoor-air unit.

Direct-drive fan arrays provide turndown and service redundancy for continuous production areas.

Sensible trim cooling removes room and fan heat without duplicating full latent treatment.

Préoccupations du client produit

High cleanroom air-change rates magnify every unnecessary filter, coil and duct pressure loss in the recirculation path.

A small coil and filter bank create excessive fan energy at high recirculation volume.Expanded face area lowers component velocity and reduces pressure drop.
Terminal filter loading gradually reduces cleanroom air changes.Variable-speed fans maintain the scheduled airflow or duct static-pressure setpoint.
One large fan failure stops production airflow.A multi-fan array can continue at reduced capacity while one fan position is isolated.
Mixing humid outdoor air into the return stream destabilizes room moisture.A separate conditioned fresh-air connection introduces air at a controlled dew point.

Les applications typiques

Large pharmaceutical cleanroomsSemiconductor clean productionMedical-device assembly hallsBattery manufacturing clean zonesHigh-air-change laboratories

Paramètres techniques

The following ranges describe a high-volume cleanroom recirculation AHU casing.

Matériaux de basePolyurethane or high-density mineral-wool acoustic and thermal panel insulation
Panneau épaisseur50–60 mm double-skin casing
Largeur effective1200–4200 mm nominal casing width
Longueur maximaleUp to 9000 mm for filters, coil, fan array and mixing section
Acier face épaisseur0.6–1.0 mm galvanized or coated casing skins
Densité Core42–45 kg/m³ polyurethane or 80–110 kg/m³ mineral wool
Conductivité thermique0.022–0.040 W/(m·K) depending on panel core
surface finiePowder-coated outer skin with smooth galvanized or coated inner skin
Type jointGasketed low-leakage panel joints and bolted modular fan/coil sections
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

EC fan wall with N+1 fan positionChilled-water or refrigerant trim coilReturn prefilter or fine-filter bankTop, side or end return and supply connections

Planning a Recirculation Air Handling Unit specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.