Recirculation の空気取り扱いの単位

A high-volume return-air unit that recirculates filtered cleanroom air while handling sensible load and maintaining stable airflow.
  • High Recirculation Airflow
  • Low Fan Energy Path
  • Stable Sensible Cooling
  • Variable-Speed Air Volume
見積もりリクエスト 製品案内

商品紹介

The recirculation air handling unit moves the high air volume needed for particle dilution without repeatedly conditioning the entire stream as outdoor air. Return air passes through accessible filters, a cooling or trim coil and direct-drive fans before returning to ceiling filters or supply distribution. Fresh conditioned air can enter upstream as a smaller measured quantity. Large coil face area and low-pressure-drop components reduce fan energy, while airflow control compensates for terminal filter loading and operating mode changes.

主要な特徴

Large filter and coil face areas keep pressure drop low across the high recirculation volume.

A small conditioned fresh-air connection can be mixed with the return stream without oversizing the outdoor-air unit.

Direct-drive fan arrays provide turndown and service redundancy for continuous production areas.

Sensible trim cooling removes room and fan heat without duplicating full latent treatment.

お客様の製品に関する懸念事項

High cleanroom air-change rates magnify every unnecessary filter, coil and duct pressure loss in the recirculation path.

A small coil and filter bank create excessive fan energy at high recirculation volume.Expanded face area lowers component velocity and reduces pressure drop.
Terminal filter loading gradually reduces cleanroom air changes.Variable-speed fans maintain the scheduled airflow or duct static-pressure setpoint.
One large fan failure stops production airflow.A multi-fan array can continue at reduced capacity while one fan position is isolated.
Mixing humid outdoor air into the return stream destabilizes room moisture.A separate conditioned fresh-air connection introduces air at a controlled dew point.

典型的な用途

Large pharmaceutical cleanroomsSemiconductor clean productionMedical-device assembly hallsBattery manufacturing clean zonesHigh-air-change laboratories

技術的なパラメータ

The following ranges describe a high-volume cleanroom recirculation AHU casing.

コア材料Polyurethane or high-density mineral-wool acoustic and thermal panel insulation
パネルの厚さ50–60 mm double-skin casing
有効幅1200–4200 mm nominal casing width
最大長さUp to 9000 mm for filters, coil, fan array and mixing section
鋼鉄の厚さを直面する0.6–1.0 mm galvanized or coated casing skins
コア密度42–45 kg/m³ polyurethane or 80–110 kg/m³ mineral wool
熱伝導率0.022–0.040 W/(m·K) depending on panel core
表面仕上げPowder-coated outer skin with smooth galvanized or coated inner skin
ジョイントタイプGasketed low-leakage panel joints and bolted modular fan/coil sections
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

EC fan wall with N+1 fan positionChilled-water or refrigerant trim coilReturn prefilter or fine-filter bankTop, side or end return and supply connections