Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
Системы контроля за чистыми помещениями и экологического мониторинга

Датчик шума

A fixed sound-level sensor that converts cleanroom acoustic pressure into a continuous weighted noise value for trend monitoring and alarms.
  • Measurement Microphone
  • Continuous dB Output
  • Frequency and Time Weighting
  • Remote Alarm Integration
Запрос котировки Просмотреть продукты

Введение продукции

The cleanroom noise level sensor combines a measurement microphone, preamplifier and digital signal processing in a wall or ceiling transmitter. Selected frequency and time weighting produce a consistent sound-level value for room trends, occupational studies or equipment-noise alarms. The microphone is protected by an acoustically transparent cap that can be inspected or replaced. Analog and digital outputs transfer the measured level without streaming room audio, preserving the function as a sound-pressure monitor rather than a recording device.

Основные характеристики

A calibrated measurement microphone responds predictably across the selected acoustic band.

Configurable frequency and time weighting supports different monitoring objectives.

Continuous dB output reveals gradual equipment-noise changes as well as threshold events.

The transmitter reports numeric sound level without capturing intelligible audio recordings.

Обеспокоенность клиентов продуктами

Fixed noise monitoring must distinguish meaningful changes from short impacts and must not be confused with voice recording.

Brief door impacts create repeated high-noise alarms.Appropriate time weighting and alarm delay reduce response to momentary events.
Microphone dust protection changes the acoustic response.An acoustically specified protective cap maintains airflow while shielding the element.
Staff assume the device records conversations.The output is limited to sound-level data and status rather than audio content.
A rising fan or bearing noise is noticed only after failure.Long-term dB trends reveal persistent changes relative to the established room baseline.

Типичные приложения

Cleanroom equipment noise trendingLaboratory acoustic monitoringOperator comfort assessmentFan and bearing condition indication

Технические параметры

Typical construction values for a fixed cleanroom noise level sensor are shown below.

Основной материалElectret or MEMS measurement microphone with FR-4 processor board in polycarbonate enclosure
Толщина панели35-70 mm transmitter depth
эффективная ширина90-150 mm housing width
Максимальная длинаUp to 220 mm housing length with microphone head
Толщина линий стали0-0.8 mm; optional stainless microphone guard
Плотность ядра1180-1220 kg/m³ for polycarbonate transmitter housing
Теплопроводимость0.19-0.22 W/(m·K) for polycarbonate enclosure material
Поверхностная отделкаSmooth white housing with black acoustic cap and blue status indicator
Объединенный типWall or ceiling bracket with replaceable microphone cap and rear output terminal
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

A or C frequency weightingFast or slow time weightingAnalog or digital outputLocal alarm indicator

Planning a Noise Sensor specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat

Главная

Продукция

Новости

О нас

Контакты