クリーンルームの壁と天井システム
シングルガラスのクリーンルームパーティション
A room-height partition formed from 12 mm toughened safety glass in a slim aluminum perimeter frame, designed to add visibility and borrowed light without the bulk of a twin-pane wall.
- 12 mm Toughened Safety Glass
- Room-Height Transparent Wall
- Slim 50 mm Glazing Frame
- Silicone-Sealed Glass Edges
商品紹介
Single-Glazed Cleanroom Partitions combine one thick safety-glass pane with a profiled aluminum frame that connects directly to adjacent modular wall panels. Replaceable snap-on covers retain the pane, and clear silicone closes the perimeter and glass-to-glass joints. The resulting partition has fewer layers and a narrower visual profile than double glazing, making it suitable where teams need open sightlines and daylight but do not require an enclosed inter-pane cavity.
主要な特徴
Toughened glass provides higher impact tolerance than ordinary annealed glazing.
Slim framing increases the transparent area within each wall module.
Snap-on retaining covers allow damaged glass to be changed without replacing neighboring panels.
Silicone perimeter seals close narrow ledges that would otherwise collect dust.
お客様の製品に関する懸念事項
Buyers assess safety-glass selection, deflection at full height, edge cleanability and replacement access.
Ordinary thin glazing may flex excessively in a tall cleanroom wall.A 12 mm toughened pane and four-sided aluminum frame create a stiffer room-height module.
Wide mullions interrupt supervision and reduce natural light between rooms.The slim glazing frame leaves most of the module transparent while retaining the pane perimeter.
Exposed glazing beads and rough silicone lines become difficult-to-wipe edges.Snap-on covers and controlled sealant joints form a continuous cleanable border.
Replacing a broken pane can disturb an entire fixed glass wall.Removable retaining profiles give direct access to the affected glass module.
典型的な用途
Electronics production viewing wallsResearch laboratory partitionsMedical-device assembly suitesClean manufacturing visitor corridorsQuality-control and inspection rooms
技術的なパラメータ
Typical dimensions for a framed single-glazed cleanroom wall are shown below.
| コア材料 | N/A — single 12 mm toughened safety-glass pane |
|---|---|
| パネルの厚さ | 50 mm glazing-frame depth |
| 有効幅 | 1200 mm standard module |
| 最大長さ | 3000 mm maximum partition height |
| 鋼鉄の厚さを直面する | N/A — glazed partition has no steel facing |
| コア密度 | N/A — monolithic glass construction has no cellular core |
| 熱伝導率 | N/A — single glazing is selected for visibility rather than thermal insulation |
| 表面仕上げ | Clear, frosted or tinted 12 mm toughened glass with powder-coated aluminum frame |
| ジョイントタイプ | Clear silicone glass joint within four-sided aluminum frame and 30 × 33 mm wall connector |
| カスタマイズ | 目的のアプリケーションおよび動作環境に基づいて利用可能 |
利用可能なオプション
Frosted privacy glassTinted safety glassLow-UV glazing filmPrinted manifestation or custom graphics