A duct-mounted cabinet with removable side doors and a positive-pressure clamping mechanism for servicing HEPA filters from either side.
  • Dual-Side Service
  • Positive Crank Seal
  • Integrated Prefilter Track
  • Welded Weatherproof Cabinet
Demander un devis. Browse les produits

Introduction de produit

This housing positions HEPA or ULPA filters perpendicular to the duct and allows them to slide in from either side. A crank or lever mechanism transfers force evenly to each filter gasket, producing a repeatable seal without access from the air face. Removable gasketed doors close both service openings, and an upstream track accepts a shallow prefilter. Standing flanges, pressure taps and challenge ports simplify integration into clean manufacturing and healthcare air systems.

Key Features

Dual access doors permit service from the side with safe working clearance.

A spring-loaded crank mechanism distributes sealing pressure across each filter row.

The separate prefilter track protects the absolute filter from coarse loading.

External pressure ports support differential-pressure monitoring without opening the cabinet.

Préoccupations du client produit

A ducted HEPA bank must be serviceable in a narrow plantroom while maintaining uniform gasket compression.

Only one side of the filter bank remains reachable after installation.Removable doors on both sides allow the usable service direction to be selected on site.
Hand-tightened clips apply unequal pressure around a large HEPA gasket.The crank mechanism applies coordinated sealing force across the filter row.
Coarse dust shortens expensive HEPA filter life.An integral prefilter track captures larger particles before the final filter.
A door seal leaks after repeated maintenance cycles.Square reinforced doors and high-memory perimeter gasketing maintain contact around the opening.

Les applications typiques

Cleanroom air-handler final filtrationHospital supply and exhaust systemsPharmaceutical HVAC branchesLaboratory ventilationOutdoor equipment filter sections

Paramètres techniques

Representative materials and dimensions for a ducted side-access HEPA housing are listed below.

Matériaux de baseWelded galvanized or 304 stainless-steel cabinet with steel filter tracks and crank clamp
Panneau épaisseur1.5–2.0 mm all-welded housing panels
Largeur effective365–3920 mm for half- to six-filter-wide assemblies
Longueur maximaleUp to 3920 mm bank length in modular multi-filter arrangements
Acier face épaisseur1.5–2.0 mm galvanized or 304 stainless steel
Densité CoreApproximately 7850 kg/m³ for galvanized-steel cabinet components
Conductivité thermiqueApproximately 45–60 W/(m·K) for galvanized-steel construction
surface finieMill-galvanized, brushed stainless steel or weather-resistant powder coat
Type jointStanding duct flanges, dual gasketed access doors and crank-compressed filter gasket
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Galvanized or 304 stainless steelGasket- or gel-seal filter rackTwo-inch prefilter trackChallenge injection and scan ports