Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Filtres à air et filtration chimique / Safe-Change Filter Housing
Filtres à air et filtration chimique

Filtre de changement sûr

A compact containment housing with a protected service sleeve and mistake-resistant clamp for changing loaded filters without opening them to the room.
  • Protected Service Sleeve
  • Mistake-Resistant Clamping
  • Inspection Window
  • Compact Containment Module
Demander un devis. Browse les produits

Introduction de produit

The safe-change housing integrates a flexible replacement barrier into a compact welded enclosure. A clear service window confirms that the filter and bag are present before the door is released, while the internal shaft cannot reach its locked position unless the filter is correctly seated. The housing can accept particulate or molecular cells and connect into a modular exhaust line. Its removable lightweight door and external operating handle reduce the number of actions carried out inside the barrier.

Key Features

A protected service sleeve isolates the filter throughout the exchange sequence.

Mechanical poka-yoke geometry prevents clamping before the element is fully seated.

A viewing window permits filter-position checks without removing the access door.

Corner-connected modules build larger banks while maintaining a rigid sealing frame.

Préoccupations du client produit

Contained change is only reliable when the filter, clamp, service barrier and access door are used in the correct sequence.

A technician begins service without confirming that the barrier bag is present.The inspection window provides an external view of the installed filter and change sleeve.
A partially seated filter is clamped and creates a hidden bypass path.The locating feature blocks the clamp from closing until the element reaches its sealing position.
A heavy access door is awkward to handle through protective equipment.A removable lightweight door reduces handling force around the service opening.
Adding a second filtration stage creates an unsealed field transition.Matched modular interfaces connect stages with a continuous compression gasket.

Les applications typiques

Pharmaceutical potent-compound exhaustMicrobiology research suitesAnimal disease facilitiesHospital isolation ventilationChemical sampling enclosures

Paramètres techniques

Typical construction ranges for a compact safe-change filter housing are shown below.

Matériaux de baseWelded 304 stainless-steel enclosure with stainless internal filter rack and clamp shaft
Panneau épaisseur1.2–2.5 mm enclosure panels
Largeur effective305–1220 mm for one- or two-filter-wide modules
Longueur maximaleUp to 2000 mm per assembled multi-stage section
Acier face épaisseur1.2–2.5 mm 304 stainless-steel casing and sealing frame
Densité CoreApproximately 8000 kg/m³ for 304 stainless-steel structural parts
Conductivité thermiqueApproximately 14.5–16.5 W/(m·K) for the compact 304 stainless module
surface finieCleaned brushed stainless steel with smooth continuous welds
Type jointModular corner-bolted connection with continuous gasket, protected service collar and safety clamp
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Particulate or molecular filter sectionIntegrated viewing windowUpstream and downstream isolationPressure and aerosol test ports

Planning a Safe-Change Filter Housing specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat

Accueil

Produits

Actualités

À propos

Contact