Unité modulaire de traitement de l'air
- Configurable Treatment Sections
- Thermal-Break Double Skin
- Low-Leakage Panel Joints
- Service-Friendly Access
Introduction de produit
The modular air handling unit is assembled from matched casing sections around a rigid corrosion-protected frame. Filter banks, chilled-water or direct-expansion coils, heating coils, humidifiers, energy-recovery devices and plug-fan arrays can be placed in the required process order. Smooth internal panels and gasketed access doors support routine cleaning, while thermally separated skins limit condensation on the outer casing. Shipping splits allow large units to pass through plant-room access routes without sacrificing a continuous sealed air path after assembly.
Key Features
Double-skin insulated panels reduce casing heat gain, radiated fan noise and surface condensation risk.
Gasketed block joints and access doors maintain a controlled air path while permitting component replacement.
Direct-drive plug fans or fan arrays provide stable airflow control without belts in the supply airstream.
Préoccupations du client produit
A cleanroom air handler must fit the building, deliver the scheduled treatment sequence and remain accessible without creating uncontrolled leakage paths.
Les applications typiques
Paramètres techniques
Typical construction ranges for a configurable cleanroom modular air-handling unit are listed below.
| Matériaux de base | Rigid polyurethane foam or high-density mineral-wool insulation within double-skin casing panels |
|---|---|
| Panneau épaisseur | 50–70 mm insulated double-skin casing |
| Largeur effective | 1000–4000 mm nominal casing width |
| Longueur maximale | Up to 12000 mm assembled length using bolted shipping sections |
| Acier face épaisseur | 0.5–1.0 mm inner and outer sheet, selected by casing duty |
| Densité Core | 40–45 kg/m³ polyurethane or 80–120 kg/m³ mineral wool |
| Conductivité thermique | 0.022–0.040 W/(m·K), depending on insulation material |
| surface finie | Powder-coated galvanized outer skin with galvanized or 304 stainless-steel cleanable inner skin |
| Type joint | Thermal-break aluminum frame with compression-gasketed panel and block joints |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Modular Air Handling Unit specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien