Ihr One-Stop - Lieferant für Reinraumausrüstung und Essentials für aseptische EinrichtungenInternationale Projektunterstützung
Open mobile navigationClose mobile navigation
Reinraum HVAC und Luftbehandlung Ausrüstung

Modularer Luftbehandlungseinheit

A section-built double-skin air handler that combines filtration, thermal treatment, fan and humidity-control functions in a serviceable cleanroom HVAC platform.
  • Configurable Treatment Sections
  • Thermal-Break Double Skin
  • Low-Leakage Panel Joints
  • Service-Friendly Access

Produkteinführung

The modular air handling unit is assembled from matched casing sections around a rigid corrosion-protected frame. Filter banks, chilled-water or direct-expansion coils, heating coils, humidifiers, energy-recovery devices and plug-fan arrays can be placed in the required process order. Smooth internal panels and gasketed access doors support routine cleaning, while thermally separated skins limit condensation on the outer casing. Shipping splits allow large units to pass through plant-room access routes without sacrificing a continuous sealed air path after assembly.

Key Features

Standardized casing modules allow treatment functions to be arranged in the actual airflow sequence rather than forced into a fixed package.

Double-skin insulated panels reduce casing heat gain, radiated fan noise and surface condensation risk.

Gasketed block joints and access doors maintain a controlled air path while permitting component replacement.

Direct-drive plug fans or fan arrays provide stable airflow control without belts in the supply airstream.

Kunden Produktbedenken

A cleanroom air handler must fit the building, deliver the scheduled treatment sequence and remain accessible without creating uncontrolled leakage paths.

A fixed factory package cannot accommodate the required filter, coil and humidifier sequence.Individual modules are arranged around the specified psychrometric process and pressure-drop budget.
Large equipment cannot pass through the available plant-room opening.Engineered shipping splits divide the casing into manageable sections with gasketed field block joints.
Cold casing bridges create condensation and staining around panel frames.Thermal-break profiles and continuous insulation separate the inner and outer metal skins.
Fan maintenance interrupts the entire cleanroom supply system.Multi-fan arrays can provide staged capacity and allow one fan position to be isolated for service.

Typische Anwendungen

Pharmaceutical cleanroom HVAC plantsBiotechnology production suitesMedizinische Geräte HerstellungElectronics cleanroomsLaboratory air-treatment systems

Technische Parameter

Typical construction ranges for a configurable cleanroom modular air-handling unit are listed below.

Core MaterialRigid polyurethane foam or high-density mineral-wool insulation within double-skin casing panels
Panel Dicke50–70 mm insulated double-skin casing
Effektive Breite1000–4000 mm nominal casing width
Maximale LängeUp to 12000 mm assembled length using bolted shipping sections
Stahl facing Dicke0.5–1.0 mm inner and outer sheet, selected by casing duty
Kerndichte40–45 kg/m³ polyurethane or 80–120 kg/m³ mineral wool
Thermische Leitfähigkeit0.022–0.040 W/(m·K), depending on insulation material
Oberfläche FinishPowder-coated galvanized outer skin with galvanized or 304 stainless-steel cleanable inner skin
Gemeinsamer TypThermal-break aluminum frame with compression-gasketed panel and block joints
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

Chilled-water, hot-water, steam or DX coilsPlug-fan array or single EC fan sectionBag, compact and terminal filter stagesHumidifier, dehumidifier and heat-recovery modules

Planning a Modular Air Handling Unit specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Sprechen Sie mit unserem Team
E-Mail uns WhatsApp WeChat

Startseite

Produkte

Neuigkeiten

Über uns

Kontakt