موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
إضاءة الغرف النظيفة والمعدات الكهربائية

لوحة محرك التردد المتغير

A sealed drive cabinet that regulates fan or pump speed while organizing isolation, bypass, filtering and motor connections.
  • Door-Mounted VFD Keypad
  • Motor Speed Regulation
  • Input and Output Protection
  • Bypass and Network Options
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The VFD panel integrates a variable-speed drive with incoming isolation, protection, control transformer, motor terminals and optional bypass contactors. A sealed door-mounted keypad exposes speed, current and fault information without opening the cabinet. Internal component spacing, shield termination and filtered ventilation or sealed cooling address the heat and electrical noise associated with pulse-width-modulated motor control.

الخصائص الرئيسية

The remote keypad displays operating frequency, load and fault history through the closed door.

Input isolation and branch protection provide a clear electrical service point.

Shield clamps and separated control wiring reduce interference from motor output cables.

A bypass arrangement can operate the motor across line when process continuity requires it.

Sealed thermal management prevents an open fan path into the cleanroom.

مخاوف المنتج للعملاء

A drive saves energy and improves pressure control, but its heat, harmonics and high-frequency motor output require a considered enclosure and wiring layout.

Opening the cabinet is required just to read or reset a drive fault.A sealed door keypad provides status and authorized control externally.
Motor output cables inject noise into low-level sensors.Separated routing, shield termination and optional output filters control interference.
Drive heat raises the cabinet temperature in a sealed room.Sized heat dissipation or a closed-loop exchanger removes heat without open airflow.
A drive failure stops a critical ventilation fan.An optional electrically interlocked bypass path supports defined backup operation.

تطبيقات نموذجية

Cleanroom AHU supply fansExhaust fan controlVariable-speed chilled-water circulation pumpsProcess air blowers

المعلمات الفنية

Typical configurable construction ranges for a variable frequency drive panel are listed below.

المواد الأساسيةSteel or stainless enclosure with variable frequency drive, isolator, protection, contactors, filters and copper wiring
سمك اللوحة250-600 mm enclosure depth
العرض الفعال400-1200 mm usable cabinet width
الحد الأقصى الطولUp to 2200 mm floor-standing cabinet height
الصلب يواجه سمك1.5-2.0 mm enclosure body and door panels
الكثافة الأساسيةApproximately 7850-8000 kg/m³ for steel or stainless enclosure material
الموصلية الحرارية14-60 W/(m·K) depending on stainless or carbon-steel cabinet
إنهاء السطحLight-grey or white powder coat, or brushed stainless, with black keypad and colored status lamps
نوع المشتركGasketed hinged door with sealed keypad bezel, separated power/control glands and bonded shield bar
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Manual or automatic bypassInput reactor and output filterNetwork communication gatewayWall or floor-standing enclosure

Planning a Variable Frequency Drive Panel specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat