O محلل نقاء الأكسجين

A compact portable oxygen purity analyzer with a direct percent-O₂ display, controlled sample flow and a clean quick-connect path for checking oxygen-rich product gas at the point of use.
  • Direct oxygen-purity display.
  • Single controlled sample path.
  • Portable benchtop field operation.
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This single-gas analyzer combines a protected benchtop indicator, one visible variable-area flowmeter and a fine sample-flow control in a portable enclosure. Oxygen-rich gas enters through a front quick connection, passes through a short clean sample path and reaches a dedicated percent-oxygen sensing cell before controlled venting. The display shows the stabilized oxygen concentration directly, while four fixed keys provide access to calibration, hold, range and stored-result functions. A removable sensor-service cover, calibration port, folding top handle and stable feet support routine checks around oxygen generation, filling and distribution equipment without adding the multiple channels of a general gas-quality test case.

الخصائص الرئيسية

Dedicated percent-oxygen measurement presents oxygen purity directly rather than combining unrelated particle, moisture or oil channels.

One clear variable-area flowmeter and one fine adjustment knob make the sample condition visible and repeatable during stabilization.

Short low-volume wetted path and a single inlet connection help reduce purge time and trapped ambient air between sampling points.

Four-button interface provides straightforward calibration, display hold, range selection and result storage without a complex multi-screen panel.

Separate protected calibration access supports span checks without exposing the main sample fitting to unnecessary handling.

Compact enclosure, folding handle and four anti-slip feet allow stable benchtop use and easy movement between oxygen outlets.

مخاوف المنتج للعملاء

Reliable oxygen-purity measurement depends on a leak-tight purged sample path, stable flow and pressure, a sensing principle compatible with the background gas and calibration that represents the actual measurement condition.

Ambient air trapped in the tube can make an oxygen-rich sample read low and stabilize slowly.Keep the sample line short, make a leak-tight connection and purge the complete wetted path at the selected flow before recording the stable value.
Excess inlet pressure or flow can disturb the sensing cell and bias the result.Reduce the source pressure appropriately, adjust the single flow-control knob gradually and keep the flowmeter within the configured operating band.
A sensor principle suitable for one background gas may be affected by another gas or by reactive contaminants.Select the percent-oxygen cell for the expected gas matrix and review possible cross-interference, condensation and hydrocarbon exposure before sampling.
Calibration uncertainty can be mistaken for a change in oxygen purity.Use a suitable traceable span gas, match the calibration flow and pressure to the measurement condition and record the calibration date with the test result.

تطبيقات نموذجية

Pressure-swing-adsorption oxygen generator checksOxygen cylinder filling and distribution spot testsMedical and laboratory oxygen supply verificationIndustrial oxygen pipeline quality monitoringOxygen-rich process-gas commissioning and maintenance

المعلمات الفنية

Representative construction for a portable oxygen purity analyzer is listed below; sensor principle, measurement range, flow setting, pressure conditioning and wetted materials should be selected for the oxygen source and gas matrix.

المواد الأساسيةPC/ABS portable enclosure with anodized-aluminum internal frame, 316L stainless-steel wetted fittings, borosilicate flow tube, PTFE sample tubing and a percent-oxygen sensing cell selected for the background gas
سمك اللوحةTypically 2.0-3.0 mm for the molded enclosure and front-panel structures
العرض الفعالApproximately 260-330 mm across the compact benchtop enclosure
الحد الأقصى الطولApproximately 300-380 mm from front sample connection to the rear enclosure edge, excluding the detachable tube
الصلب يواجه سمكTypically 0.8-1.2 mm for internal electromagnetic shields and stainless sensor-support brackets
الكثافة الأساسيةApproximately 1100-1200 kg/m³ for the PC/ABS enclosure components
الموصلية الحراريةApproximately 0.19-0.22 W/(m·K) for the PC/ABS enclosure components
إنهاء السطحWarm-white fine-texture housing, deep-teal protective bezel and handle accents, blue-white LCD, charcoal controls, clear flow tube, satin stainless fittings and transparent PTFE sample tubing
نوع المشتركSingle front quick-connect sample inlet with detachable PTFE tube, panel-mounted flow control, protected calibration access and a keyed removable sensor-service cover
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Paramagnetic sensing configuration for non-depleting percent-oxygen measurementElectrochemical sensing configuration for selected oxygen-rich gas matricesAlternative sample-flow and inlet-pressure conditioning rangesStainless compression, barb or quick-coupling inlet kitsRechargeable battery pack for portable spot checksUSB data export and configurable analog output