Rectangular Duct Silencer

A straight rectangular sound attenuator with aerodynamic splitters that absorbs fan and airflow noise within the duct path.
  • Aerodynamic Acoustic Splitters
  • Straight-Through Air Path
  • Perforated Protective Liners
  • Cleanroom Media Options
Alıntı isteği Browse ürünleri

Ürün tanıtımı

A rectangular duct silencer places parallel acoustic splitters inside a sealed galvanized casing. Perforated metal faces expose sound energy to the protected absorptive media while maintaining a defined straight airflow passage. Splitter thickness, air gap and overall length are selected to balance insertion loss against system pressure drop. For hygiene-sensitive air, polymer film liners or packless resonant construction isolate fibrous media from the airstream.

Ana Özellikler

Parallel splitter geometry provides broad-band attenuation without changing the direction of airflow.

Aerodynamic noses and tails reduce turbulence where air enters and leaves each baffle.

Perforated metal or film-protected faces prevent erosion of acoustic fill into the air stream.

Low-, medium- and high-velocity configurations match different pressure-drop allowances.

Müşteri Ürün Sorunları

A duct silencer must reduce the relevant frequency bands without consuming the fan pressure needed for filters and terminal devices.

Fan blade-pass noise travels directly through the supply main.Selected splitter spacing and length absorb energy in the dominant octave bands.
A restrictive silencer increases fan energy and reduces cleanroom airflow.Air-gap area and aerodynamic splitter profiles are sized for the scheduled face velocity.
Fibrous acoustic media is unacceptable in a critical supply stream.Film-lined or packless construction isolates or eliminates exposed fibrous fill.
The silencer casing leaks around splitter penetrations and seams.Sealed outer construction maintains the same leakage duty as the connected duct system.

Tipik uygulamalar

Air-handling-unit discharge noise controlCleanroom supply-air mainsLaboratory exhaust systemsFan intake and outlet plenumsMechanical-room duct penetrations

Teknik parametreler

Representative construction ranges for a rectangular HVAC duct silencer are summarized below.

Temel malzemelerHigh-density glass fiber, mineral wool or packless resonant acoustic elements
Panel kalınlığı100–300 mm acoustic splitter thickness
Effective Width (Etkili Genişlik)200–1600 mm duct connection width
Maksimum uzunluk600–2400 mm silencer casing length
Çelik yüz yüze kalınlığı0.8–1.2 mm galvanized casing and perforated liner
Core Density (Çekirdek Yoğunluğu)32–64 kg/m³ absorptive acoustic media
Termal İletkenlik0.034–0.041 W/(m·K) for straight-splitter absorptive fiber media
Yüzey bitirmeG90 galvanized casing with perforated galvanized, film-lined or stainless airstream faces
Ortak tipRectangular flange connection matched to duct size with sealed casing seams
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Absorptive, film-lined or packless constructionGalvanized, aluminum or stainless casingLow-, medium- or high-velocity splitter geometryExtended casing for enhanced low-frequency attenuation

Planning a Rectangular Duct Silencer specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim