Ana Sayfa / Ürünler / Temiz Oda Hizmet Sistemi / Chemical Exhaust Cabinet
Temiz Oda Hizmet Sistemi

Kimyasal Egzoz Kabine

Floor-standing ducted polypropylene chemical exhaust cabinet with a clear vertical sash, smooth work chamber, rear baffle, chemical-resistant worktop and lower service cabinet for corrosive laboratory tasks.
  • Welded polypropylene chamber for corrosive chemical service
  • Adjustable clear sash and rear baffle support stable capture
  • Top duct collar connects to a separately selected exhaust system
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The Chemical Exhaust Cabinet is a floor-standing ducted polypropylene fume cupboard that captures vapors at the work opening and conveys them to an external exhaust system. Its white welded polypropylene chamber, smooth rear baffle and chemical-resistant work surface are suited to many acid, alkali and trace-metal laboratory operations. A counterbalanced clear sash provides an adjustable working opening while separating the operator from the process. The displayed cabinet includes one top exhaust collar, one airflow monitor, one light enclosure, two covered service outlets, one small cup sink and a ventilated lower double-door service cabinet. The external fan, duct route, discharge location, face velocity, utilities and chemical compatibility are selected as a complete ventilation system.

Ana Özellikler

Welded white polypropylene chamber resists many corrosive laboratory chemicals and is easy to wipe clean

A vertical clear safety-glass sash provides visibility and a physical barrier at the work opening

The rear baffle distributes extract air across upper and lower capture zones instead of relying on one top opening

A tapered top collar provides a defined connection to the building exhaust duct

The smooth chemical-resistant worktop contains routine drips and supports straightforward decontamination

A local airflow monitor can warn when capture conditions move below the configured operating band

The light is isolated above the work chamber to reduce internal projections and contamination traps

Covered service outlets and remote utility controls keep common connections accessible outside the primary work zone

The lower cabinet separates service routing from the active work chamber and provides removable access panels

Modular widths and service arrangements allow the enclosure to match the intended task and laboratory layout

Müşteri Ürün Sorunları

A ducted cabinet only contains vapors when the enclosure, room air supply, duct, fan and discharge operate together. Chemical compatibility and airflow behavior must be checked for the actual procedure.

Room drafts or rapid sash movement can pull contaminants out of the work openingLocate the cabinet away from doors and strong diffusers, use a deliberate sash position and balance room supply air with the exhaust demand.
An undersized or high-resistance duct can leave acceptable fan speed but inadequate face captureCalculate the complete duct pressure loss, size the external fan accordingly and verify airflow at the cabinet after installation.
A reagent may attack the worktop, sash seal, duct, fan or service fitting even when polypropylene is compatibleReview the whole wetted and exposed material set against each chemical, concentration and temperature before use.
Large apparatus can block the rear baffle and create stagnant zones inside the chamberElevate bulky equipment where practical, keep baffle slots clear and confirm capture with the intended equipment layout.
Using the lower cabinet for incompatible chemical storage can expose utilities and increase incident severityDefine the base-cabinet function separately and use a purpose-designed, ventilated storage module only for compatible materials.
A display reading can be misleading if the sensor, alarm point or sash position is not maintainedInspect the monitor and sash routinely and verify cabinet containment and airflow using the site's scheduled test method.

Tipik uygulamalar

Acid and alkali preparation in analytical and quality-control laboratoriesTrace-metal sample digestion where a metal-free polypropylene interior is preferredWet-chemistry work in pharmaceutical, biotechnology and clean-manufacturing laboratoriesElectronics and semiconductor laboratories handling compatible corrosive reagentsBattery-material, plating and surface-treatment laboratory proceduresGeneral chemical handling that requires ducted source containment rather than recirculation

Teknik parametreler

The selected catalogue basis is a 1240 mm wide, 800 mm deep and approximately 2450 mm high floor-standing ducted cabinet with an 8 mm white polypropylene body, 980 x 570 x 700 mm nominal work chamber, manual clear sash, phenolic worktop and one top 250 mm-class exhaust collar. The fixed ten-row schema uses panel labels; Steel Facing Thickness therefore records that the welded polymer body has no metal facing. Blower, duct, face-velocity setpoint, sash stop, worktop, sink and utilities remain selectable for the intended procedure.

Temel malzemelerWelded white PP-H chamber and base-cabinet panels with a clear safety-glass sash, removable polypropylene baffle and chemical-resistant phenolic worktop
Panel kalınlığı8 mm nominal polypropylene carcass and chamber panel thickness for the selected display basis
Effective Width (Etkili Genişlik)1240 mm nominal external cabinet width with approximately 980 mm internal working width
Maksimum uzunlukApproximately 2450 mm nominal overall height including base cabinet and top exhaust connection
Çelik yüz yüze kalınlığı0 mm steel facing; the exposed carcass and work chamber are welded polypropylene
Core Density (Çekirdek Yoğunluğu)Approximately 915 kg/m³ representative density for PP-H sheet material
Termal İletkenlikApproximately 0.22 W/(m·K) for representative PP-H sheet material
Yüzey bitirmeSmooth porcelain-white polypropylene exterior and chamber, clear sash, dark chemical-resistant worktop and restrained functional control colors
Ortak tipThermally welded polypropylene carcass seams with gasketed removable baffle, vertically guided sash and flanged top exhaust collar
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Cabinet widths of approximately 1000, 1200, 1500 or 1800 mmPolypropylene, phenolic, epoxy-resin or ceramic work surfacesManual or counterbalanced vertical sash arrangementsAlternative clear sash materials for the intended chemical and impact exposureAirflow monitor with local low-flow indication and dry-contact outputRemote water, gas, vacuum and electrical service fittingsCup sink, drip tray and compatible drain connectionVentilated or service-only lower cabinet configurationsExternal corrosion-resistant fan and compatible duct packageTapered exhaust collars and duct sizes matched to the required airflow