แสงสว่างห้องสะอาดและอุปกรณ์ไฟฟ้า
ระบบโทรห้องสะอาด
A supervised call-and-confirmation system that lets cleanroom personnel request assistance through large sealed wall buttons.
- Large Sealed Call Button
- Visible Call Confirmation
- Supervised Control Circuit
- Remote Acknowledge and Reset
การแนะนําสินค้า
The cleanroom call system connects flush wall call points to corridor indicators, an operator annunciator or a network server. A large colored membrane or stainless push button registers the request and illuminates to confirm it was received. Separate acknowledge and reset logic prevents a call from disappearing silently, while supervised wiring reports open-circuit or device faults.
คุณสมบัติที่สําคัญ
A colored illuminated ring confirms that the system recorded the request.
Supervised wiring distinguishes a real call from a broken connection.
Remote annunciation identifies the originating room or call point.
Defined acknowledge and reset stages keep active requests visible until handled.
ความกังวลของลูกค้าเกี่ยวกับผลิตภัณฑ์
A simple push button is insufficient when users need confirmation, room identification and assurance that a broken wire has not disabled the call path.
A small button is hard to locate and press through gloves.A large high-contrast sealed actuator provides an obvious tactile target.
The caller cannot tell whether the signal reached an operator.A local light and optional tone confirm registration immediately.
A cable fault looks the same as a quiet inactive system.Supervised inputs raise a distinct trouble condition for open or short circuits.
Calls are cleared before assistance actually arrives.Separate acknowledge and local reset steps preserve the request workflow.
การใช้งานทั่วไป
Cleanroom assistance requestsGowning room support callsLaboratory emergency pointsMaterial airlock pickup calls
พารามิเตอร์ทางเทคนิค
Typical configurable construction ranges for a cleanroom call system are listed below.
| วัสดุหลัก | Stainless flush plates with sealed call/reset controls, LED indicators, supervised controller and low-voltage wiring |
|---|---|
| ความหนาของแผง | 1.5-3.0 mm cleanroom call-point plate thickness |
| ความกว้างที่มีประสิทธิภาพ | 86-240 mm call-station face width |
| ความยาวสูงสุด | Up to 320 mm overall station height |
| ความหนาของเหล็กหันหน้า | 1.5-3.0 mm SUS304/SUS316L front plate |
| ความหนาแน่นหลัก | Approximately 7900-8000 kg/m³ for the stainless call-point plate |
| การนําความร้อน | 14-16 W/(m·K) for the stainless front plate |
| เสร็จสิ้นพื้นผิว | Fine-brushed stainless with red, blue, green or amber illuminated sealed buttons |
| ประเภทร่วม | Flush gasketed wall plate with sealed actuators and supervised rear controller terminal connection |
| การปรับแต่ง | สามารถใช้ได้ตามแอปพลิเคชันที่ตั้งใจไว้และสภาพแวดล้อมการทํางาน |
ตัวเลือกที่มีอยู่
Call, reset and emergency functionsSingle-room or networked annunciationAudible and visual confirmationPull-cord or wall-button input